|   | 
Details
   web
Records
Author Canazei, M.; Pohl, W.; Weninger, J.; Bliem, H.; Weiss, E.M.; Koch, C.; Berger, A.; Firulovic, B.; Marth, C.
Title Effects of adjustable dynamic bedroom lighting in a maternity ward Type Journal Article
Year 2019 Publication Journal of Environmental Psychology Abbreviated Journal Journal of Environmental Psychology
Volume 62 Issue Pages 59-66
Keywords Human Health
Abstract There exists initial evidence for beneficial daylight effects in hospital bedrooms. However, study results with automatically controlled dynamic bedroom lights were so far inconclusive. It can be hypothesized that inclusion of critically ill patients and unpleasant fixed bright light stimuli so far could have masked non-visual light effects on patient's sleep, mood and circadian physiology.

Therefore, a temporarily adjustable dynamic light was installed in double bedrooms in a maternity clinic. Although mothers were exposed to fixed morning bright light under dynamic light they were allowed to adjust light intensities the rest of the day. In contrast, light colours were automatically changed over 24 h and could not be altered. Double bedrooms with standard switchable light were utilized as active control condition.

A sample of 72 women, giving birth to healthy term babies, were randomly assigned to bedrooms with dynamic or standard light. Light conditions adjusted by mothers, sleep quality, mood and diurnal melatonin level, as well as physical activity levels of mothers and neonates, were recorded.

Mothers exposed themselves and their babies to higher daytime and lower evening light levels under dynamic light compared to standard light after the period of fixed morning bright light exposure had ended. Although no overall effects on maternal parameters could be observed under dynamic light, we could reveal an earlier daily onset of neonatal physical activity levels in these bedrooms.

To conclude, this study indicates that an adjustable dynamic light may substantially affect indoor light exposure in a maternity ward. Further studies are necessary to explore light effects on mothers and substantiate study results on neonates.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language (up) Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0272-4944 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number GFZ @ kyba @ Serial 2232
Permanent link to this record
 

 
Author Martínez-Ruiz, V.; Valenzuela-Martínez, M.; Lardelli-Claret, P.; Molina-Soberanes, D.; Moreno-Roldán, E.; Jiménez-Mejías, E.
Title Factors related to the risk of pedestrian fatality after a crash in Spain, 1993–2013 Type Journal Article
Year 2019 Publication Journal of Transport & Health Abbreviated Journal Journal of Transport & Health
Volume 12 Issue Pages 279-289
Keywords Public Safety
Abstract Introduction

The aim of this study was to quantify the magnitude of association between pedestrian fatalities during the first 24 h after a crash and pedestrian-, driver-, vehicle- and environment-related characteristics in Spain from 1993 to 2013.

Methods

Data were analyzed for all 203,622 traffic crashes involving a pedestrian and a motor vehicle recorded in the Spanish Registry of Road Crashes with Victims. After multiple imputation for missing values, crude (CMRR) and adjusted mortality rate ratios (AMRR) were obtained for each variable with Poisson regression models.

Results

Pedestrian risk of death after a crash increased nearly exponentially with pedestrian age. Male sex, committing an infraction and having a physical defect were also associated with a higher risk of death (AMRR 1.27, 95%CI 1.17–1.37 for physical defect). Regarding driver-related factors associated with pedestrian fatalities, visual defects (AMRR 1.21, 95%CI 1.08–1.37) and the commission of a speed infraction (AMRR 2.59, 95%CI 2.43–2.76) increased the risk. Heavy vehicles (trucks, vans, buses) and the presence of passengers were also associated with a higher risk of pedestrian death. The risk of pedestrian death was lower for crashes that occurred between 12:00 and 14:00, in good light conditions, at intersections, and when the pedestrian was on a sidewalk. Risk was higher in crashes in rural areas with fewer than 5000 inhabitants.

Conclusions

We identified several factors strongly associated with the risk of pedestrian fatality; some of these factors are analyzed here for the first time. This knowledge is potentially useful in the design and prioritization of measures intended to increase pedestrian safety.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language (up) Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2214-1405 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number GFZ @ kyba @ Serial 2236
Permanent link to this record
 

 
Author Cao, X.; Hu, Y.; Zhu, X.; Shi, F.; Zhuo, L.; Chen, J.
Title A simple self-adjusting model for correcting the blooming effects in DMSP-OLS nighttime light images Type Journal Article
Year 2019 Publication Remote Sensing of Environment Abbreviated Journal Remote Sensing of Environment
Volume 224 Issue Pages 401-411
Keywords Remote Sensing
Abstract Night-time light (NTL) data from the Defense Meteorological Satellite Program (DMSP) Operation Linescan System (OLS) provide important observations of human activities; however, DMSP-OLS NTL data suffer from problems such as saturation and blooming. This research developed a self-adjusting model (SEAM) to correct blooming effects in DMSP-OLS NTL data based on a spatial response function and without using any ancillary data. By assuming that the pixels adjacent to the background contain no lights (i.e., pseudo light pixels, PLPs), the blooming effect intensity, a parameter in the SEAM model, can be estimated by pixel-based regression using PLPs and their neighboring light sources. SEAM was applied to all of China, and its performance was assessed for twelve cities with different population sizes. The results show that SEAM can largely reduce the blooming effect in the original DMSP-OLS dataset and enhance its quality. The images after blooming effect correction have higher spatial similarity with Suomi National Polar-orbiting Partnership Visible Infrared Imaging Radiometer Suite (VIIRS) images and higher spatial variability than the original DMSP-OLS data. We also found that the average effective blooming distance is approximately 3.5 km in China, which may be amplified if the city is surrounded by water surfaces, and that the blooming effect intensity is positively correlated to atmospheric quality. The effectiveness of the proposed model will improve the capacity of DMSP-OLS images for mapping the urban extent and modeling socioeconomic parameters.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language (up) Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0034-4257 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number GFZ @ kyba @ Serial 2239
Permanent link to this record
 

 
Author Hu, T.; Huang, X.
Title A novel locally adaptive method for modeling the spatiotemporal dynamics of global electric power consumption based on DMSP-OLS nighttime stable light data Type Journal Article
Year 2019 Publication Applied Energy Abbreviated Journal Applied Energy
Volume 240 Issue Pages 778-792
Keywords Remote Sensing
Abstract Timely and reliable estimation of electricity power consumption (EPC) is essential to the rational deployment of electricity power resources. Nighttime stable light (NSL) data from the Defense Meteorological Satellite Program Operational Linescan System (DMSP-OLS) have the potential to model global 1-km gridded EPC. A processing chain to estimate EPC includes: (1) NSL data correction; and (2) regression model between EPC statistics and NSL data. For the global gridded EPC estimation, the current approach is to correct the global NSL image in a uniform manner and establish the linear relationships between NSL and EPC. However, the impacts of local socioeconomic inconsistencies on the NSL correction and model establishment are not fully considered. Therefore, in this paper, we propose a novel locally adaptive method for global EPC estimation. Firstly, we set up two options (with or without the correction) for each local area considering the global NSL image is not saturated everywhere. Secondly, three directions (forward, backward, or average) are alternatives for the inter-annual correction to remove the discontinuity effect of NSL data. Thirdly, four optional models (linear, logarithmic, exponential, or second-order polynomial) are adopted for the EPC estimation of each local area with different socioeconomic dynamic. Finally, the options for each step constitute all candidate processing chains, from which the optimal one is adaptively chosen for each local area based on the coefficient of determination. The results demonstrate that our product outperforms the existing one, at global, continental, and national scales. Particularly, the proportion of countries/districts with a high accuracy (MARE (mean of the absolute relative error)  ≤ 10%) increases from 17.8% to 57.8% and the percentage of countries/districts with inaccurate results (MARE > 50%) decreases sharply from 23.0% to 3.7%. This product can enhance the detailed understanding of the spatiotemporal dynamics of global EPC.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language (up) Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0306-2619 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number GFZ @ kyba @ Serial 2242
Permanent link to this record
 

 
Author Middleton, B.; Stone, B.M.; Arendt, J.
Title Human circadian phase in 12:12 h, 200:<8 lux and 1000:<8 lux light-dark cycles, without scheduled sleep or activity Type Journal Article
Year 2002 Publication Neuroscience Letters Abbreviated Journal Neuroscience Letters
Volume 329 Issue 1 Pages 41-44
Keywords Human Health
Abstract The light levels required to maintain human circadian phase in the absence of other strong time cues are not defined. We investigated circadian phase in two groups of men, living in partial temporal isolation, exposed to 12 h:12 h light:dark cycles of: (A) 200:<8 lux, broad spectrum white light for 14 days; and (B) 1000:<8lux for 14 days. The rhythm variables measured were urinary 6-sulphatoxymelatonin, rectal temperature, activity and rest (actigraphy and sleep logs). In 200:<8 lux four/six individuals showed phase delays. Exposure to 1000:<8 lux appeared to maintain synchronisation of rest-activity to 24 h, but with a significant overall phase advance of 0.81 h in temperature. These observations suggest that domestic intensity light does not maintain phase without scheduled sleep/activity, possibly due to indirect effects on behaviour influencing light exposure.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language (up) Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0304-3940 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number GFZ @ kyba @ Serial 2247
Permanent link to this record