toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author (up) Tapia Ayuga, C.; Sánchez de Miguel, A.; Zamorano Calvo, J. url  openurl
  Title LICA-UCM lamps spectral database Type Report
  Year 2015 Publication unpublished Abbreviated Journal  
  Volume Issue Pages  
  Keywords Lighting; Instrumentation; technical report; Madrid; Spain; spectroscopy; spectra  
  Abstract Spectra of the lamps that are used for public lighting and ornamental purposes have been obtained with a portable spectrograph around Madrid city. The database is presented in this report along with a description of the procedures.  
  Address Grupo UCM de Astrofísica Extragaláctica e Instrumentación Astronómica, Madrid  
  Corporate Author Thesis  
  Publisher Place of Publication Madrid Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title LICA Reports Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium PDF  
  Area Expedition Conference  
  Notes Request to add by CK even though non-peer-reviewed Approved no  
  Call Number IDA @ john @ Serial 1094  
Permanent link to this record
 

 
Author (up) Tauc, M.J.; Fristrup, K.M.; Repasky, K.S.; Shaw, J.A. url  doi
openurl 
  Title Field demonstration of a wing-beat modulation lidar for the 3D mapping of flying insects Type Journal Article
  Year 2019 Publication OSA Continuum Abbreviated Journal OSA Continuum  
  Volume 2 Issue 2 Pages 332  
  Keywords Instrumentation; Animals  
  Abstract We describe a wing-beat modulation lidar system designed for the 3D mapping of flying insects in ecological or entomological studies. To better understand the signals from this instrument, we analyzed simulated signals to identify how they were affected by various imperfections, such as variations in the spacing and amplitude of each individual wing-beat reflection. In addition, a radiometric model was used to estimate signal-to-noise ratio to gain insight into the relationships between the optical system design and insect parameters (e.g., wing size, reflectivity, or diffusivity).  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2578-7519 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2209  
Permanent link to this record
 

 
Author (up) Voigt, L.P.; Reynolds, K.; Mehryar, M.; Chan, W.S.; Kostelecky, N.; Pastores, S.M.; Halpern, N.A. url  doi
openurl 
  Title Monitoring sound and light continuously in an intensive care unit patient room: A pilot study Type Journal Article
  Year 2016 Publication Journal of Critical Care Abbreviated Journal Journal of Critical Care  
  Volume 38 Issue 21 Pages 5952-5961  
  Keywords Instrumentation; Human Health  
  Abstract Purpose

To determine the feasibility of continuous recording of sound and light in the intensive care unit (ICU).

Materials and Methods

Four one-hour baseline scenarios in an empty ICU patient room by day and night (doors open or closed and maximal or minimal lighting) and two daytime scenarios simulating a stable and unstable patient (quiet or loud devices and staff) were conducted. Sound and light levels were continuously recorded using a commercially available multisensor monitor and transmitted via the hospital's network to a cloud-based data storage and management system.

Results

The empty ICU room was loud with similar mean sound levels for the day and night simulations of 45–46 dBA. Mean levels for maximal lighting during day and night ranged from 1306–1812 lux and mean levels for minimum lighting were 1–3 lux. The mean sound levels for the stable and unstable patient simulations were 61 and 81 dBA, respectively. The mean light levels were 349 lux for the stable patient and 1947 lux for the unstable patient.

Conclusions

Combined sound and light can be continuously and easily monitored in the ICU setting. Incorporating sound and light monitors in ICU rooms may promote an enhanced patient and staff centered healing environment.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0883-9441 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1614  
Permanent link to this record
 

 
Author (up) Wahl, F.; Kantermann, T.; Amft, O. url  doi
openurl 
  Title How much Light do you get? Estimating Daily Light Exposure using Smartphones Type Conference Article
  Year 2014 Publication Proceedings of the 2014 ACM International Symposium on Wearable Computers Abbreviated Journal Proc. of the 2014 ACM International Symposium on Wearable Computers  
  Volume n/a Issue n/a Pages 43-46  
  Keywords Instrumentation; light exposure; context inference, light intensity; light intake; circadian clock; circadian rhythm; mobile sensing  
  Abstract We present an approach to estimate a persons light exposure using smartphones. We used web-sourced weather reports combined with smartphone light sensor data, time of day, and indoor/outdoor information, to estimate illuminance around the user throughout a day. Since light dominates every human’s circadian rhythm and influences the sleep-wake cycle, we developed a smartphone-based system that does not re- quire additional sensors for illuminance estimation. To evaluate our approach, we conducted a free-living study with 12 users, each carrying a smartphone, a head-mounted light reference sensor, and a wrist-worn light sensing device for six consecutive days. Estimated light values were compared to the head-mounted reference, the wrist-worn device and a mean value estimate. Our results show that illuminance could be estimated at less than 20% error for all study participants, outperforming the wrist-worn device. In 9 out of 12 participants the estimation deviated less than 10% from the reference measurements.  
  Address ACTLab, Chair of Sensor Technology, University of Passau (florian.wahl@uni-passau.de)  
  Corporate Author Thesis  
  Publisher ACM Place of Publication Editor  
  Language English Summary Language English Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 1206  
Permanent link to this record
 

 
Author (up) Wallner, S. url  doi
openurl 
  Title Usage of Vertical Fisheye-Images to Quantify Urban Light Pollution on Small Scales and the Impact of LED Conversion Type Journal Article
  Year 2019 Publication Journal of Imaging Abbreviated Journal J. Imaging  
  Volume 5 Issue 11 Pages 86  
  Keywords Instrumentation  
  Abstract The aim of this work was to develop an easy and quick technique for characterizing various lighting situations, that is, single lamps or illuminated signs and to quantify impacts on small scales like streets, buildings and near areas. The method uses a DSLR-camera equipped with fisheye-lens and the software Sky Quality Camera, both commonly used as part of night sky imagery in the light pollution community, to obtain information about luminance and correlated colour temperature. As a difference to its usual build-up, observed light emitting sources were captured by pointing the camera towards analysed objects, that is, images were taken via vertical plane imaging with very short exposure times under one second. Results have proven that this technique provides a practical way to quantify the lighting efficacy in a certain place or area, as a quantitative analysis of the direct emission towards the observer and the illumination on surroundings, that is, street surfaces, sidewalks and buildings, was performed. When conducting lamp conversions, the method can be used to characterize the gradient of change and could be a useful tool for municipalities to find the optimal lighting solution. The paper shows examples of different lighting situations like single lamps of different types, also containing various luminaires, illuminated billboards or buildings and impacts of the lighting transition to LEDs in the city of Eisenstadt, Austria. The horizontal fisheye method is interdisciplinary applicable, for example, being suitable for lighting management, to sustainability and energy saving purposes.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2313-433X ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2749  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: