Author Qiu, S.; Shao, X.; Cao, C.; Uprety, S. url  doi
openurl 
  Title Feasibility demonstration for calibrating Suomi-National Polar-Orbiting Partnership Visible Infrared Imaging Radiometer Suite day/night band using Dome C and Greenland under moon light Type Journal Article
  Year 2016 Publication Journal of Applied Remote Sensing Abbreviated Journal J. Appl. Remote Sens  
  Volume 10 Issue 1 Pages (down) 016024  
  Keywords Remote Sensing; Instrumentation  
  Abstract The day/night band (DNB) of the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard Suomi National Polar-orbiting Partnership (Suomi-NPP) represents a major advancement in night time imaging capabilities. DNB covers almost seven orders of magnitude in its dynamic range from full sunlight to half-moon. To achieve this large dynamic range, it uses four charge-coupled device arrays in three gain stages. The low gain stage (LGS) gain is calibrated using the solar diffuser. In operations, the medium and high gain stage values are determined by multiplying the gain ratios between the medium gain stage, and LGS, and high gain stage (HGS) and LGS, respectively. This paper focuses on independently verifying the radiometric accuracy and stability of DNB HGS using DNB observations of ground vicarious calibration sites under lunar illumination at night. Dome C in Antarctica in the southern hemisphere and Greenland in the northern hemisphere are chosen as the vicarious calibration sites. Nadir observations of these high latitude regions by VIIRS are selected during perpetual night season, i.e., from April to August for Dome C and from November to January for Greenland over the years 2012 to 2013. Additional selection criteria, such as lunar phase being more than half-moon and no influence of straylight effects, are also applied in data selection. The lunar spectral irradiance model, as a function of Sun–Earth–Moon distances and lunar phase, is used to determine the top-of-atmosphere reflectance at the vicarious site. The vicariously derived long-term reflectance from DNB observations agrees with the reflectance derived from Hyperion observations. The vicarious trending of DNB radiometric performance using DOME-C and Greenland under moon light shows that the DNB HGS radiometric variability (relative accuracy to lunar irradiance model and Hyperion observation) is within 8%. Residual variability is also discussed.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1931-3195 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1372  
Permanent link to this record
 

 
Author Yao, Q.; Wang, H.; Dai, Q.; Shi, F. url  doi
openurl 
  Title Quantification assessment of light pollution of façade lighting display in Shenzhen, China Type Journal Article
  Year 2020 Publication Optics Express Abbreviated Journal Opt. Express  
  Volume 28 Issue 9 Pages (down) 14100  
  Keywords Lighting; Instrumentation  
  Abstract In this work, we investigated 39 façade lighting displays, all of which consisted of tri-chromatic light sources, namely blue-, green-, and red- light units, in Shenzhen, China. We extracted the spectral characteristics of the mean peak wavelength/full-width at half-maximum,and proposed universal spectral models. We further established the ‘chromaticity-performance’ relation to quantitatively assess the impact of light pollution on typical species based on corresponding action spectra. The findings provide a low-cost, fast and precise approach to assess light pollution of complicated light environment, and may help reduce energy waste and adverse environmental consequences associated with light pollution.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1094-4087 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2893  
Permanent link to this record
 

 
Author Schnitt, S.; Ruhtz, T.; Fischer, J.; Hölker, F.; Kyba, C.C.M. url  doi
openurl 
  Title Temperature stability of the sky quality meter Type Journal Article
  Year 2013 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)  
  Volume 13 Issue 9 Pages (down) 12166-12174  
  Keywords *Artifacts; Atmosphere/*analysis; Environmental Monitoring/*instrumentation; Equipment Design; Equipment Failure Analysis; Photometry/*instrumentation; Reproducibility of Results; Sensitivity and Specificity; Temperature; *Transducers; Sky Quality Meter; SQM  
  Abstract The stability of radiance measurements taken by the Sky Quality Meter (SQM)was tested under rapidly changing temperature conditions during exposure to a stable light field in the laboratory. The reported radiance was found to be negatively correlated with temperature, but remained within 7% of the initial reported radiance over a temperature range of -15 degrees C to 35 degrees C, and during temperature changes of -33 degrees C/h and +70 degrees C/h.This is smaller than the manufacturer's quoted unit-to-unit systematic uncertainty of 10%,indicating that the temperature compensation of the SQM is adequate under expected outdoor operating conditions.  
  Address Institute for Space Sciences, Freie Universitat Berlin, Carl-Heinrich-Becker-Weg 6-10, Berlin 12165, Germany. christopher.kyba@wew.fu-berlin.de  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:24030682; PMCID:PMC3821345 Approved no  
  Call Number IDA @ john @ Serial 194  
Permanent link to this record
 

 
Author Stone, J.E.; Phillips, A.J.K.; Ftouni, S.; Magee, M.; Howard, M.; Lockley, S.W.; Sletten, T.L.; Anderson, C.; Rajaratnam, S.M.W.; Postnova, S. url  doi
openurl 
  Title Generalizability of A Neural Network Model for Circadian Phase Prediction in Real-World Conditions Type Journal Article
  Year 2019 Publication Scientific Reports Abbreviated Journal Sci Rep  
  Volume 9 Issue 1 Pages (down) 11001  
  Keywords Human Health; Instrumentation  
  Abstract A neural network model was previously developed to predict melatonin rhythms accurately from blue light and skin temperature recordings in individuals on a fixed sleep schedule. This study aimed to test the generalizability of the model to other sleep schedules, including rotating shift work. Ambulatory wrist blue light irradiance and skin temperature data were collected in 16 healthy individuals on fixed and habitual sleep schedules, and 28 rotating shift workers. Artificial neural network models were trained to predict the circadian rhythm of (i) salivary melatonin on a fixed sleep schedule; (ii) urinary aMT6s on both fixed and habitual sleep schedules, including shift workers on a diurnal schedule; and (iii) urinary aMT6s in rotating shift workers on a night shift schedule. To determine predicted circadian phase, center of gravity of the fitted bimodal skewed baseline cosine curve was used for melatonin, and acrophase of the cosine curve for aMT6s. On a fixed sleep schedule, the model predicted melatonin phase to within +/- 1 hour in 67% and +/- 1.5 hours in 100% of participants, with mean absolute error of 41 +/- 32 minutes. On diurnal schedules, including shift workers, the model predicted aMT6s acrophase to within +/- 1 hour in 66% and +/- 2 hours in 87% of participants, with mean absolute error of 63 +/- 67 minutes. On night shift schedules, the model predicted aMT6s acrophase to within +/- 1 hour in 42% and +/- 2 hours in 53% of participants, with mean absolute error of 143 +/- 155 minutes. Prediction accuracy was similar when using either 1 (wrist) or 11 skin temperature sensor inputs. These findings demonstrate that the model can predict circadian timing to within +/- 2 hours for the vast majority of individuals on diurnal schedules, using blue light and a single temperature sensor. However, this approach did not generalize to night shift conditions.  
  Address School of Physics, University of Sydney, Sydney, New South Wales, Australia  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2045-2322 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:31358781; PMCID:PMC6662750 Approved no  
  Call Number GFZ @ kyba @ Serial 2667  
Permanent link to this record
 

 
Author den Outer, P.; Lolkema, D.; Haaima, M.; van der Hoff, R.; Spoelstra, H.; Schmidt, W. url  doi
openurl 
  Title Intercomparisons of nine sky brightness detectors Type Journal Article
  Year 2011 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)  
  Volume 11 Issue 10 Pages (down) 9603-9612  
  Keywords Calibration; Darkness; *Extraterrestrial Environment; Humans; Light; Luminescent Measurements; Netherlands; *Optical Phenomena; Optics and Photonics/*instrumentation/*methods; Sky Quality Meter; artificial lighting; intercalibration; intercomparison; light pollution; night sky brightness  
  Abstract Nine Sky Quality Meters (SQMs) have been intercompared during a night time measurement campaign held in the Netherlands in April 2011. Since then the nine SQMs have been distributed across The Netherlands and form the Dutch network for monitoring night sky brightness. The goal of the intercomparison was to infer mutual calibration factors and obtain insight into the variability of the SQMs under different meteorological situations. An ensemble average is built from the individual measurements and used as a reference to infer the mutual calibration factors. Data required additional synchronization prior to the calibration determination, because the effect of moving clouds combined with small misalignments emerges as time jitter in the measurements. Initial scatter of the individual instruments lies between +/-14%. Individual night time sums range from -16% to +20%. Intercalibration reduces this to 0.5%, and -7% to +9%, respectively. During the campaign the smallest luminance measured was 0.657 +/- 0.003 mcd/m(2) on 12 April, and the largest value was 5.94 +/- 0.03 mcd/m(2) on 2 April. During both occurrences interfering circumstances like snow cover or moonlight were absent.  
  Address National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3720 BA Bilthoven, The Netherlands. peter.den.outer@rivm.nl  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:22163715; PMCID:PMC3231263 Approved no  