toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Rayleigh, L. url  doi
openurl 
  Title A Photoelectric Method of Measuring the Light of the Night Sky with Studies of the Course of Variation through the Night Type Journal Article
  Year 1929 Publication Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences Abbreviated Journal Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences  
  Volume 124 Issue 794 Pages 395-408  
  Keywords Instrumentation; Night Sky Brightness  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) 1364-5021 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2396  
Permanent link to this record
 

 
Author Schnitt, S.; Ruhtz, T.; Fischer, J.; Hölker, F.; Kyba, C.C.M. url  doi
openurl 
  Title Temperature stability of the sky quality meter Type Journal Article
  Year 2013 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)  
  Volume 13 Issue 9 Pages 12166-12174  
  Keywords *Artifacts; Atmosphere/*analysis; Environmental Monitoring/*instrumentation; Equipment Design; Equipment Failure Analysis; Photometry/*instrumentation; Reproducibility of Results; Sensitivity and Specificity; Temperature; *Transducers; Sky Quality Meter; SQM  
  Abstract The stability of radiance measurements taken by the Sky Quality Meter (SQM)was tested under rapidly changing temperature conditions during exposure to a stable light field in the laboratory. The reported radiance was found to be negatively correlated with temperature, but remained within 7% of the initial reported radiance over a temperature range of -15 degrees C to 35 degrees C, and during temperature changes of -33 degrees C/h and +70 degrees C/h.This is smaller than the manufacturer's quoted unit-to-unit systematic uncertainty of 10%,indicating that the temperature compensation of the SQM is adequate under expected outdoor operating conditions.  
  Address Institute for Space Sciences, Freie Universitat Berlin, Carl-Heinrich-Becker-Weg 6-10, Berlin 12165, Germany. christopher.kyba@wew.fu-berlin.de  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:24030682; PMCID:PMC3821345 Approved no  
  Call Number IDA @ john @ Serial 194  
Permanent link to this record
 

 
Author den Outer, P.; Lolkema, D.; Haaima, M.; van der Hoff, R.; Spoelstra, H.; Schmidt, W. url  doi
openurl 
  Title Intercomparisons of nine sky brightness detectors Type Journal Article
  Year 2011 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)  
  Volume 11 Issue 10 Pages 9603-9612  
  Keywords Calibration; Darkness; *Extraterrestrial Environment; Humans; Light; Luminescent Measurements; Netherlands; *Optical Phenomena; Optics and Photonics/*instrumentation/*methods; Sky Quality Meter; artificial lighting; intercalibration; intercomparison; light pollution; night sky brightness  
  Abstract Nine Sky Quality Meters (SQMs) have been intercompared during a night time measurement campaign held in the Netherlands in April 2011. Since then the nine SQMs have been distributed across The Netherlands and form the Dutch network for monitoring night sky brightness. The goal of the intercomparison was to infer mutual calibration factors and obtain insight into the variability of the SQMs under different meteorological situations. An ensemble average is built from the individual measurements and used as a reference to infer the mutual calibration factors. Data required additional synchronization prior to the calibration determination, because the effect of moving clouds combined with small misalignments emerges as time jitter in the measurements. Initial scatter of the individual instruments lies between +/-14%. Individual night time sums range from -16% to +20%. Intercalibration reduces this to 0.5%, and -7% to +9%, respectively. During the campaign the smallest luminance measured was 0.657 +/- 0.003 mcd/m(2) on 12 April, and the largest value was 5.94 +/- 0.03 mcd/m(2) on 2 April. During both occurrences interfering circumstances like snow cover or moonlight were absent.  
  Address National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3720 BA Bilthoven, The Netherlands. peter.den.outer@rivm.nl  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:22163715; PMCID:PMC3231263 Approved no  
  Call Number IDA @ john @ Serial 196  
Permanent link to this record
 

 
Author den Outer, P.; Lolkema, D.; Haaima, M.; van der Hoff, R.; Spoelstra, H.; Schmidt, W. url  doi
openurl 
  Title Stability of the Nine Sky Quality Meters in the Dutch Night Sky Brightness Monitoring Network Type Journal Article
  Year 2015 Publication Sensors Abbreviated Journal Sensors  
  Volume 15 Issue 4 Pages 9466-9480  
  Keywords Instrumentation  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ christopher.kyba @ Serial 1157  
Permanent link to this record
 

 
Author Dobler, G.; Ghandehari, M.; Koonin, S.E.; Sharma, M.S. url  doi
openurl 
  Title A Hyperspectral Survey of New York City Lighting Technology Type Journal Article
  Year 2016 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)  
  Volume 16 Issue 12 Pages 2047  
  Keywords Remote Sensing; Instrumentation; Lighting  
  Abstract Using side-facing observations of the New York City (NYC) skyline, we identify lighting technologies via spectral signatures measured with Visible and Near Infrared (VNIR) hyperspectral imaging. The instrument is a scanning, single slit spectrograph with 872 spectral channels from 0.4-1.0 mu m. With a single scan, we are able to clearly match the detected spectral signatures of 13 templates of known lighting types. However, many of the observed lighting spectra do not match those that have been measured in the laboratory. We identify unknown spectra by segmenting our observations and using Template-Activated Partition (TAP) clustering with a variety of underlying unsupervised clustering methods to generate the first empirically-determined spectral catalog of roughly 40 urban lighting types. We show that, given our vantage point, we are able to determine lighting technology use for both interior and exterior lighting. Finally, we find that the total brightness of our scene shows strong peaks at the 570 nm Na – II , 595 nm Na – II and 818 nm Na – I lines that are common in high pressure sodium lamps, which dominate our observations.  
  Address NYU Center for Urban Science and Progress, 1 MetroTech Center, Brooklyn, NY 11201, USA. mohit.sharma@nyu.edu  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:27929391 Approved no  
  Call Number LoNNe @ kyba @ Serial 1567  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: