toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Kyba, C.C.M.; Holker, F. url  doi
openurl 
  Title Window illumination should be expected to poorly correlate with satellite brightness measurements Type Journal Article
  Year 2012 Publication Chronobiology International Abbreviated Journal Chronobiol Int  
  Volume 29 Issue 1 Pages 87-8  
  Keywords Commentary; Instrumentation; Human Health  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) 0742-0528 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:22217106 Approved no  
  Call Number GFZ @ kyba @ Serial 2533  
Permanent link to this record
 

 
Author Voigt, L.P.; Reynolds, K.; Mehryar, M.; Chan, W.S.; Kostelecky, N.; Pastores, S.M.; Halpern, N.A. url  doi
openurl 
  Title Monitoring sound and light continuously in an intensive care unit patient room: A pilot study Type Journal Article
  Year 2016 Publication Journal of Critical Care Abbreviated Journal Journal of Critical Care  
  Volume 38 Issue 21 Pages 5952-5961  
  Keywords Instrumentation; Human Health  
  Abstract Purpose

To determine the feasibility of continuous recording of sound and light in the intensive care unit (ICU).

Materials and Methods

Four one-hour baseline scenarios in an empty ICU patient room by day and night (doors open or closed and maximal or minimal lighting) and two daytime scenarios simulating a stable and unstable patient (quiet or loud devices and staff) were conducted. Sound and light levels were continuously recorded using a commercially available multisensor monitor and transmitted via the hospital's network to a cloud-based data storage and management system.

Results

The empty ICU room was loud with similar mean sound levels for the day and night simulations of 45–46 dBA. Mean levels for maximal lighting during day and night ranged from 1306–1812 lux and mean levels for minimum lighting were 1–3 lux. The mean sound levels for the stable and unstable patient simulations were 61 and 81 dBA, respectively. The mean light levels were 349 lux for the stable patient and 1947 lux for the unstable patient.

Conclusions

Combined sound and light can be continuously and easily monitored in the ICU setting. Incorporating sound and light monitors in ICU rooms may promote an enhanced patient and staff centered healing environment.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) 0883-9441 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1614  
Permanent link to this record
 

 
Author Alamús, R.; Bará, S.; Corbera, J.; Escofet, J.; Palà , V.; Pipia, L.; Tardà, A. url  doi
openurl 
  Title Ground-based hyperspectral analysis of the urban nightscape Type Journal Article
  Year 2017 Publication ISPRS Journal of Photogrammetry and Remote Sensing Abbreviated Journal ISPRS Journal of Photogrammetry and Remote Sensing  
  Volume 124 Issue Pages 16-26  
  Keywords Instrumentation; Remote Sensing  
  Abstract Airborne hyperspectral cameras provide the basic information to estimate the energy wasted skywards by outdoor lighting systems, as well as to locate and identify their sources. However, a complete characterization of the urban light pollution levels also requires evaluating these effects from the city dwellers standpoint, e.g. the energy waste associated to the excessive illuminance on walls and pavements, light trespass, or the luminance distributions causing potential glare, to mention but a few. On the other hand, the spectral irradiance at the entrance of the human eye is the primary input to evaluate the possible health effects associated with the exposure to artificial light at night, according to the more recent models available in the literature. In this work we demonstrate the possibility of using a hyperspectral imager (routinely used in airborne campaigns) to measure the ground-level spectral radiance of the urban nightscape and to retrieve several magnitudes of interest for light pollution studies. We also present the preliminary results from a field campaign carried out in the downtown of Barcelona.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) 0924-2716 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1613  
Permanent link to this record
 

 
Author Zheng, Q.; Weng, Q.; Wang, K. url  doi
openurl 
  Title Developing a new cross-sensor calibration model for DMSP-OLS and Suomi-NPP VIIRS night-light imageries Type Journal Article
  Year 2019 Publication ISPRS Journal of Photogrammetry and Remote Sensing Abbreviated Journal ISPRS Journal of Photogrammetry and Remote Sensing  
  Volume 153 Issue Pages 36-47  
  Keywords Remote Sensing; Instrumentation  
  Abstract Night-time light (NTL) data provides a great opportunity to monitor human activities and settlements. Currently, global-scale NTL data are acquired by two satellite sensors, i.e., DMSP-OLS and VIIRS, but the data collected by the satellites are not compatible. To address this issue, we proposed a method for generating long-term and consistent NTL data. First, a logistic model was employed to estimate and smooth the missing DMSP-OLS data. Second, the Lomb-Scargle Periodogram technique was used to statistically examine the presence of seasonality of monthly VIIRS time series. The seasonal effect, noisy and unstable observations in VIIRS were eliminated by the BFAST time-series decomposition algorithm. Then, we proposed a residuals corrected geographically weighted regression model (GWRc) to generate DMSP-like VIIRS data. A consistent NTL time series from 1996 to 2017 was formed by combining the DMSP-OLS and synthetic DMSP-like VIIRS data. Our assessment shows that the proposed GWRc model outperformed existing methods (e.g., power function model), yielding a lower regression RMSE (6.36), a significantly improved pixel-level NTL intensity consistency (SNDI = 82.73, R2 = 0.986) and provided more coherent results when used for urban area extraction. The proposed method can be used to extend NTL time series, and in conjunction with the upcoming yearly VIIRS data and Black Marble daily VIIRS data, it is possible to support long-term NTL-based studies such as monitoring light pollution in ecosystems, and mapping human activities.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) 0924-2716 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2361  
Permanent link to this record
 

 
Author Bierman, A.; Figueiro, M.G.; Rea, M.S. url  doi
openurl 
  Title Measuring and predicting eyelid spectral transmittance Type Journal Article
  Year 2011 Publication Journal of Biomedical Optics Abbreviated Journal J Biomed Opt  
  Volume 16 Issue 6 Pages 067011  
  Keywords Instrumentation; Human Health  
  Abstract The purpose of the present study was to objectively quantify the spectral transmittance of the eyelid. Reported here are data acquired using a technique that was developed to provide practical and accurate measurements of eyelid transmittance across the visible portion of the electromagnetic spectrum. The empirical data were analyzed in terms of the absorption and scattering characteristics of the constituents of skin to develop a method for predicting eyelid transmission. Results showed that the eyelid has a much higher optical density at short wavelengths than previously published. The mean +/- standard deviation (s.d.) optical density of the eyelid from 450 to 650 nm was 2.1 +/- 0.3 with an optical density range among subjects of approximately 1.0. The study results indicate that skin pigmentation is poorly correlated with eyelid transmission; eyelid transmission is most affected by wavelength-independent macromolecules in the eyelid as well as its overall thickness.  
  Address Rensselaer Polytechnic Institute, Lighting Research Center, 21 Union Street, Troy, New York 12180, USA  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) 1083-3668 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:21721832 Approved no  
  Call Number LoNNe @ kyba @ Serial 1530  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: