Author Zhang, G.; Li, L.; Jiang, Y.; Shen, X.; Li, D. url  doi
openurl 
  Title On-Orbit Relative Radiometric Calibration of the Night-Time Sensor of the LuoJia1-01 Satellite Type Journal Article
  Year 2018 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)  
  Volume 18 Issue (down) 12 Pages  
  Keywords Instrumentation; Remote Sensing  
  Abstract The LuoJia1-01 satellite can acquire high-resolution, high-sensitivity nighttime light data for night remote sensing applications. LuoJia1-01 is equipped with a 4-megapixel CMOS sensor composed of 2048 x 2048 unique detectors that record weak nighttime light on Earth. Owing to minute variations in manufacturing and temporal degradation, each detector's behavior varies when exposed to uniform radiance, resulting in noticeable detector-level errors in the acquired imagery. Radiometric calibration helps to eliminate these detector-level errors. For the nighttime sensor of LuoJia1-01, it is difficult to directly use the nighttime light data to calibrate the detector-level errors, because at night there is no large-area uniform light source. This paper reports an on-orbit radiometric calibration method that uses daytime data to estimate the relative calibration coefficients for each detector in the LuoJia1-01 nighttime sensor, and uses the calibrated data to correct nighttime data. The image sensor has a high dynamic range (HDR) mode, which is optimized for day/night imaging applications. An HDR image can be constructed using low- and high-gain HDR images captured in HDR mode. Hence, a day-to-night radiometric reference transfer model, which uses daytime uniform calibration to calibrate the detector non-uniformity of the nighttime sensor, is herein built for LuoJia1-01. Owing to the lack of calibration equipment on-board LuoJia1-01, the dark current of the nighttime sensor is calibrated by collecting no-light desert images at new moon. The results show that in HDR mode (1) the root mean square of mean for each detector in low-gain (high-gain) images is better than 0.04 (0.07) in digital number (DN) after dark current correction; (2) the DN relationship between low- and high-gain images conforms to the quadratic polynomial mode; (3) streaking metrics are better than 0.2% after relative calibration; and (4) the nighttime sensor has the same relative correction parameters at different exposure times for the same gain parameters.  
  Address State Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University, Wuhan 430079, China. drli@whu.edu.cn  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:30513817 Approved no  
  Call Number GFZ @ kyba @ Serial 2125  
Permanent link to this record
 

 
Author Coesfeld, J.; Anderson, S.; Baugh, K.; Elvidge, C.; Schernthanner, H.; Kyba, C. url  doi
openurl 
  Title Variation of Individual Location Radiance in VIIRS DNB Monthly Composite Images Type Journal Article
  Year 2018 Publication Remote Sensing Abbreviated Journal Remote Sensing  
  Volume 10 Issue (down) 12 Pages 1964  
  Keywords Remote Sensing; Instrumentation  
  Abstract With the growing size and use of night light time series from the Visible Infrared Imaging Radiometer Suite Day/Night Band (DNB), it is important to understand the stability of the dataset. All satellites observe differences in pixel values during repeat observations. In the case of night light data, these changes can be due to both environmental effects and changes in light emission. Here we examine the stability of individual locations of particular large scale light sources (e.g., airports and prisons) in the monthly composites of DNB data from April 2012 to September 2017. The radiances for individual pixels of most large light emitters are approximately normally distributed, with a standard deviation of typically 15–20% of the mean. Greenhouses and flares, however, are not stable sources. We observe geospatial autocorrelation in the monthly variations for nearby sites, while the correlation for sites separated by large distances is small. This suggests that local factors contribute most to the variation in the pixel radiances and furthermore that averaging radiances over large areas will reduce the total variation. A better understanding of the causes of temporal variation would improve the sensitivity of DNB to lighting changes.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2072-4292 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2129  
Permanent link to this record
 

 
Author Li, X.; Zhao, L.; Li, D.; Xu, H. url  doi
openurl 
  Title Mapping Urban Extent Using Luojia 1-01 Nighttime Light Imagery Type Journal Article
  Year 2018 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)  
  Volume 18 Issue (down) 11 Pages  
  Keywords Instrumentation; Remote Sensing  
  Abstract Luojia 1-01 satellite, launched on 2 June 2018, provides a new data source of nighttime light at 130 m resolution and shows potential for mapping urban extent. In this paper, using Luojia 1-01 and VIIRS nighttime light imagery, we compared several methods for extracting urban areas, including Human Settlement Index (HSI), Simple Thresholding Segmentation (STS) and SVM supervised classification. According to the accuracy assessment, the HSI method using LJ1-01 data had the best performance in urban extent extraction, which presented the largest Kappa Coefficient value, 0.834, among all the results. For the urban areas extracted by VIIRS based HSI method, the largest Kappa Coefficient value was 0.772. In contrast, the largest Kappa Coefficient values obtained by STS method were 0.79 and 0.7512 respectively when using LJ1-01 and VIIRS data, while for SVM method the values were 0.7829 and 0.7486 when using Landsat-LJ and Landsat-VIIRS composite data respectively. The experimented results demonstrated that the utilization of nighttime light imagery can largely improve the accuracy of urban extent extraction and LJ1-01 data, with a higher resolution and more abundant spatial information, can lead to better identification results than its predecessors.  
  Address Key Laboratory of the Ministry of Land and Resources for Law Evaluation Engineering, Wuhan 430074, China. xuhuimin1985_2008@163.com  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:30380616 Approved no  
  Call Number GFZ @ kyba @ Serial 2056  
Permanent link to this record
 

 
Author Wallner, S. url  doi
openurl 
  Title Usage of Vertical Fisheye-Images to Quantify Urban Light Pollution on Small Scales and the Impact of LED Conversion Type Journal Article
  Year 2019 Publication Journal of Imaging Abbreviated Journal J. Imaging  
  Volume 5 Issue (down) 11 Pages 86  
  Keywords Instrumentation  
  Abstract The aim of this work was to develop an easy and quick technique for characterizing various lighting situations, that is, single lamps or illuminated signs and to quantify impacts on small scales like streets, buildings and near areas. The method uses a DSLR-camera equipped with fisheye-lens and the software Sky Quality Camera, both commonly used as part of night sky imagery in the light pollution community, to obtain information about luminance and correlated colour temperature. As a difference to its usual build-up, observed light emitting sources were captured by pointing the camera towards analysed objects, that is, images were taken via vertical plane imaging with very short exposure times under one second. Results have proven that this technique provides a practical way to quantify the lighting efficacy in a certain place or area, as a quantitative analysis of the direct emission towards the observer and the illumination on surroundings, that is, street surfaces, sidewalks and buildings, was performed. When conducting lamp conversions, the method can be used to characterize the gradient of change and could be a useful tool for municipalities to find the optimal lighting solution. The paper shows examples of different lighting situations like single lamps of different types, also containing various luminaires, illuminated billboards or buildings and impacts of the lighting transition to LEDs in the city of Eisenstadt, Austria. The horizontal fisheye method is interdisciplinary applicable, for example, being suitable for lighting management, to sustainability and energy saving purposes.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2313-433X ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2749  
Permanent link to this record
 

 
Author Coesfeld, J.; Kuester, T.; Kuechly, H.U.; Kyba, C.C.M. url  doi
openurl 
  Title Reducing Variability and Removing Natural Light from Nighttime Satellite Imagery: A Case Study Using the VIIRS DNB Type Journal Article
  Year 2020 Publication Sensors Abbreviated Journal Sensors  
  Volume 20 Issue (down) 11 Pages 3287  
  Keywords Remote Sensing; Instrumentation  
  Abstract Temporal variation of natural light sources such as airglow limits the ability of night light sensors to detect changes in small sources of artificial light (such as villages). This study presents a method for correcting for this effect globally, using the satellite radiance detected from regions without artificial light emissions. We developed a routine to define an approximate grid of locations worldwide that do not have regular light emission. We apply this method with a 5 degree equally spaced global grid (total of 2016 individual locations), using data from the Visible Infrared Imaging Radiometer Suite (VIIRS) Day-Night Band (DNB). This code could easily be adapted for other future global sensors. The correction reduces the standard deviation of data in the Earth Observation Group monthly DNB composites by almost a factor of two. The code and datasets presented here are available under an open license by GFZ Data Services, and are implemented in the Radiance Light Trends web application.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2988  
Permanent link to this record