Author Wallner, S.
Title Usage of Vertical Fisheye-Images to Quantify Urban Light Pollution on Small Scales and the Impact of LED Conversion Type Journal Article
Year 2019 Publication Journal of Imaging Abbreviated Journal J. Imaging
Volume 5 Issue (up) 11 Pages 86
Keywords Instrumentation
Abstract The aim of this work was to develop an easy and quick technique for characterizing various lighting situations, that is, single lamps or illuminated signs and to quantify impacts on small scales like streets, buildings and near areas. The method uses a DSLR-camera equipped with fisheye-lens and the software Sky Quality Camera, both commonly used as part of night sky imagery in the light pollution community, to obtain information about luminance and correlated colour temperature. As a difference to its usual build-up, observed light emitting sources were captured by pointing the camera towards analysed objects, that is, images were taken via vertical plane imaging with very short exposure times under one second. Results have proven that this technique provides a practical way to quantify the lighting efficacy in a certain place or area, as a quantitative analysis of the direct emission towards the observer and the illumination on surroundings, that is, street surfaces, sidewalks and buildings, was performed. When conducting lamp conversions, the method can be used to characterize the gradient of change and could be a useful tool for municipalities to find the optimal lighting solution. The paper shows examples of different lighting situations like single lamps of different types, also containing various luminaires, illuminated billboards or buildings and impacts of the lighting transition to LEDs in the city of Eisenstadt, Austria. The horizontal fisheye method is interdisciplinary applicable, for example, being suitable for lighting management, to sustainability and energy saving purposes.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2313-433X ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number GFZ @ kyba @ Serial 2749
Permanent link to this record
 

 
Author Miller, S.; Straka, W.; Mills, S.; Elvidge, C.; Lee, T.; Solbrig, J.; Walther, A.; Heidinger, A.; Weiss, S.
Title Illuminating the Capabilities of the Suomi National Polar-Orbiting Partnership (NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band Type Journal Article
Year 2013 Publication Remote Sensing Abbreviated Journal Remote Sensing
Volume 5 Issue (up) 12 Pages 6717-6766
Keywords Instrumentation; satellite imagery; nighttime visible/near-infrared; moonlight
Abstract Daytime measurements of reflected sunlight in the visible spectrum have been a staple of Earth-viewing radiometers since the advent of the environmental satellite platform. At night, these same optical-spectrum sensors have traditionally been limited to thermal infrared emission, which contains relatively poor information content for many important weather and climate parameters. These deficiencies have limited our ability to characterize the full diurnal behavior and processes of parameters relevant to improved monitoring, understanding and modeling of weather and climate processes. Visible-spectrum light information does exist during the nighttime hours, originating from a wide variety of sources, but its detection requires specialized technology. Such measurements have existed, in a limited way, on USA Department of Defense satellites, but the Suomi National Polar-orbiting Partnership (NPP) satellite, which carries a new Day/Night Band (DNB) radiometer, offers the first quantitative measurements of nocturnal visible and near-infrared light. Here, we demonstrate the expanded potential for nocturnal low-light visible applications enabled by the DNB. Via a combination of terrestrial and extraterrestrial light sources, such observations are always available—expanding many current existing applications while enabling entirely new capabilities. These novel low-light measurements open doors to a wealth of new interdisciplinary research topics while lighting a pathway toward the optimized design of follow-on satellite based low light visible sensors.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2072-4292 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number LoNNe @ christopher.kyba @ Serial 468
Permanent link to this record
 

 
Author Blonski, S.; Cao, C.
Title Suomi NPP VIIRS Reflective Solar Bands Operational Calibration Reprocessing Type Journal Article
Year 2015 Publication Remote Sensing Abbreviated Journal Remote Sensing
Volume 7 Issue (up) 12 Pages 16131-16149
Keywords Instrumentation
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2072-4292 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number LoNNe @ kyba @ Serial 1310
Permanent link to this record
 

 
Author Dobler, G.; Ghandehari, M.; Koonin, S.E.; Sharma, M.S.
Title A Hyperspectral Survey of New York City Lighting Technology Type Journal Article
Year 2016 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)
Volume 16 Issue (up) 12 Pages 2047
Keywords Remote Sensing; Instrumentation; Lighting
Abstract Using side-facing observations of the New York City (NYC) skyline, we identify lighting technologies via spectral signatures measured with Visible and Near Infrared (VNIR) hyperspectral imaging. The instrument is a scanning, single slit spectrograph with 872 spectral channels from 0.4-1.0 mu m. With a single scan, we are able to clearly match the detected spectral signatures of 13 templates of known lighting types. However, many of the observed lighting spectra do not match those that have been measured in the laboratory. We identify unknown spectra by segmenting our observations and using Template-Activated Partition (TAP) clustering with a variety of underlying unsupervised clustering methods to generate the first empirically-determined spectral catalog of roughly 40 urban lighting types. We show that, given our vantage point, we are able to determine lighting technology use for both interior and exterior lighting. Finally, we find that the total brightness of our scene shows strong peaks at the 570 nm Na – II , 595 nm Na – II and 818 nm Na – I lines that are common in high pressure sodium lamps, which dominate our observations.
Address NYU Center for Urban Science and Progress, 1 MetroTech Center, Brooklyn, NY 11201, USA. mohit.sharma@nyu.edu
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1424-8220 ISBN Medium
Area Expedition Conference
Notes PMID:27929391 Approved no
Call Number LoNNe @ kyba @ Serial 1567
Permanent link to this record
 

 
Author Zhang, G.; Li, L.; Jiang, Y.; Shen, X.; Li, D.
Title On-Orbit Relative Radiometric Calibration of the Night-Time Sensor of the LuoJia1-01 Satellite Type Journal Article
Year 2018 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)
Volume 18 Issue (up) 12 Pages
Keywords Instrumentation; Remote Sensing
Abstract The LuoJia1-01 satellite can acquire high-resolution, high-sensitivity nighttime light data for night remote sensing applications. LuoJia1-01 is equipped with a 4-megapixel CMOS sensor composed of 2048 x 2048 unique detectors that record weak nighttime light on Earth. Owing to minute variations in manufacturing and temporal degradation, each detector's behavior varies when exposed to uniform radiance, resulting in noticeable detector-level errors in the acquired imagery. Radiometric calibration helps to eliminate these detector-level errors. For the nighttime sensor of LuoJia1-01, it is difficult to directly use the nighttime light data to calibrate the detector-level errors, because at night there is no large-area uniform light source. This paper reports an on-orbit radiometric calibration method that uses daytime data to estimate the relative calibration coefficients for each detector in the LuoJia1-01 nighttime sensor, and uses the calibrated data to correct nighttime data. The image sensor has a high dynamic range (HDR) mode, which is optimized for day/night imaging applications. An HDR image can be constructed using low- and high-gain HDR images captured in HDR mode. Hence, a day-to-night radiometric reference transfer model, which uses daytime uniform calibration to calibrate the detector non-uniformity of the nighttime sensor, is herein built for LuoJia1-01. Owing to the lack of calibration equipment on-board LuoJia1-01, the dark current of the nighttime sensor is calibrated by collecting no-light desert images at new moon. The results show that in HDR mode (1) the root mean square of mean for each detector in low-gain (high-gain) images is better than 0.04 (0.07) in digital number (DN) after dark current correction; (2) the DN relationship between low- and high-gain images conforms to the quadratic polynomial mode; (3) streaking metrics are better than 0.2% after relative calibration; and (4) the nighttime sensor has the same relative correction parameters at different exposure times for the same gain parameters.
Address State Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University, Wuhan 430079, China. drli@whu.edu.cn
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1424-8220 ISBN Medium
Area Expedition Conference
Notes PMID:30513817 Approved no
Call Number GFZ @ kyba @ Serial 2125