toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Choi, T.; Shao, X.; Cao, C.; Weng, F. url  doi
openurl 
  Title Radiometric Stability Monitoring of the Suomi NPP Visible Infrared Imaging Radiometer Suite (VIIRS) Reflective Solar Bands Using the Moon Type Journal Article
  Year 2016 Publication Remote Sensing Abbreviated Journal Remote Sensing  
  Volume 8 Issue 1 Pages 15  
  Keywords Instrumentation  
  Abstract The Suomi NPP (S-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) performs the scheduled lunar roll maneuver on a monthly basis. The lunar calibration coefficients and lunar F-factor are calculated by taking the ratio of the lunar observed radiance to the simulated radiance from the Miller and Turner (MT) lunar model. The lunar F-factor is also validated against that derived from the VIIRS Solar Diffuser (SD). The MT model-based lunar F-factors in general agree with SD F-factors. The Lunar Band Ratio (LBR) is also derived from two channel lunar radiances and is implemented in the National Oceanic and Atmospheric Administration (NOAA) Integrated Calibration and Validation System (ICVS) to monitor the VIIRS long-term radiometric performance. The lunar radiances at pixels are summed for each of the VIIRS Reflective Solar Bands (RSBs) and normalized by the reference band M11 which has the most stable SD-based calibration coefficient. LBRs agree with the SD based F-factor ratios within one percent. Based on analysis with these two independent lunar calibration methods, SD-based and LBR-based calibrations show a lifetime consistency. Thus, it is recommended that LBR be used for both VIIRS radiometric calibration and lifetime stability monitoring.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2072-4292 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1384  
Permanent link to this record
 

 
Author Pravettoni, M.; Strepparava, D.; Cereghetti, N.; Klett, S.; Andretta, M.; Steiger, M. url  doi
openurl 
  Title Indoor calibration of Sky Quality Meters: linearity, spectral responsivity and uncertainty analysis Type Journal Article
  Year 2016 Publication Journal of Quantitative Spectroscopy and Radiative Transfer Abbreviated Journal Journal of Quantitative Spectroscopy and Radiative Transfer  
  Volume 181 Issue in press Pages 74-86  
  Keywords Instrumentation  
  Abstract The indoor calibration of brightness sensors requires extremely low values of irradiance in the most accurate and reproducible way. In this work the testing equipment of an ISO 17025 accredited laboratory for electrical testing, qualification and type approval of solar photovoltaic modules was modified in order to test the linearity of the instruments from few mW/cm2 down to fractions of nW/cm2, corresponding to levels of simulated brightness from 6 to 19 mag/arcsec2. Sixteen Sky Quality Meter (SQM) produced by Unihedron, a Canadian manufacturer, were tested, also assessing the impact of the ageing of their protective glasses on the calibration coefficients and the drift of the instruments. The instruments are in operation on measurement points and observatories at different sites and altitudes in Southern Switzerland, within the framework of OASI, the Environmental Observatory of Southern Switzerland. The authors present the results of the calibration campaign: linearity; brightness calibration, with and without protective glasses; transmittance measurement of the glasses; and spectral responsivity of the devices. A detailed uncertainty analysis is also provided, according to the ISO 17025 standard.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0022-4073 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1399  
Permanent link to this record
 

 
Author Mills, S.; Miller, S. url  doi
openurl 
  Title VIIRS Day/Night Band--Correcting Striping and Nonuniformity over a Very Large Dynamic Range Type Journal Article
  Year 2016 Publication Journal of Imaging Abbreviated Journal J. Imaging  
  Volume 2 Issue 1 Pages 9  
  Keywords Instrumentation  
  Abstract The Suomi National Polar-orbiting (NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) Day-Night Band (DNB) measures visible and near-infrared light extending over seven orders of magnitude of dynamic range. This makes radiometric calibration difficult. We have observed that DNB imagery has striping, banding and other nonuniformities—day or night. We identified the causes as stray light, nonlinearity, detector crosstalk, hysteresis and mirror-side variation. We found that these affect both Earth-view and calibration signals. These present an obstacle to interpretation by users of DNB products. Because of the nonlinearity we chose the histogram matching destriping technique which we found is successful for daytime, twilight and nighttime scenes. Because of the very large dynamic range of the DNB, we needed to add special processes to the histogram matching to destripe all scenes, especially imagery in the twilight regions where scene illumination changes rapidly over short distances. We show that destriping aids image analysts, and makes it possible for advanced automated cloud typing algorithms. Manual or automatic identification of other features, including polar ice and gravity waves in the upper atmosphere are also discussed. In consideration of the large volume of data produced 24 h a day by the VIIRS DNB, we present methods for reducing processing time.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2313-433X ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1400  
Permanent link to this record
 

 
Author Warrant, E. url  doi
openurl 
  Title Superior vision in nocturnal insects inspires new night vision technologies Type Newspaper Article
  Year 2016 Publication SPIE Newsroom Abbreviated Journal SPIE Newsroom  
  Volume Issue Pages  
  Keywords Vision; Animals; Instrumentation  
  Abstract Algorithms that dramatically improve the quality of video sequences captured in very dim light have been developed on the basis of the neural mechanisms in nocturnal insects with excellent visual capabilities.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1818-2259 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @; GFZ @ kyba @ Serial 1418  
Permanent link to this record
 

 
Author Levin, N.; Phinn, S. url  doi
openurl 
  Title Illuminating the capabilities of Landsat 8 for mapping night lights Type Journal Article
  Year 2016 Publication Remote Sensing of Environment Abbreviated Journal Remote Sensing of Environment  
  Volume 182 Issue Pages 27-38  
  Keywords Remote Sensing; Instrumentation  
  Abstract Remote sensing of night-lights has been enhanced in recent years with the availability of the new VIIRS Day and Night band, the commercial EROS-B satellite and astronaut photographs from the International Space Station. However, dedicated space-borne multispectral sensors offering radiance calibrated night lights imagery are yet to be launched. Here we examined the capabilities of Landsat 8 to acquire night time light images of the Earth. Examining seven night-time Landsat 8 scenes, we found that brightly lit areas in both urban (Berlin, Las Vegas, Nagoya and Tel-Aviv) and gas flares (Basra, Kuwait) areas were detected in all eight bands of Landsat 8. The threshold for detection of lit areas was approximately 0.4 W/m2/μm/sr in bands 1–5 and 8 of Landsat 8. This threshold level was higher than Landsat dark noise levels, and slightly lower than post launch Landsat 8 OLI band dependent noise equivalent radiance difference levels. Drawing on this, we call on the USGS to plan an annual night-time acquisition of urban and gas flares areas globally, and to enable the performance of the future Landsat 10 to be established in a way that it will be sensitive enough to image the Earth at night, thus performing as Nightsat during the night.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0034-4257 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1452  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: