|   | 
Details
   web
Records
Author Jiang, W.; He, G.; Long, T.; Guo, H.; Yin, R.; Leng, W.; Liu, H.; Wang, G.
Title Potentiality of Using Luojia 1-01 Nighttime Light Imagery to Investigate Artificial Light Pollution Type Journal Article
Year 2018 Publication Sensors Abbreviated Journal Sensors
Volume (down) 18 Issue 9 Pages 2900
Keywords Remote Sensing; Instrumentation
Abstract The successful launch of Luojia 1-01 complements the existing nighttime light data with a high spatial resolution of 130 m. This paper is the first study to assess the potential of using Luojia 1-01 nighttime light imagery for investigating artificial light pollution. Eight Luojia 1-01 images were selected to conduct geometric correction. Then, the ability of Luojia 1-01 to detect artificial light pollution was assessed from three aspects, including the comparison between Luojia 1-01 and the Suomi National Polar-Orbiting Partnership Visible Infrared Imaging Radiometer Suite (NPP-VIIRS), the source of artificial light pollution and the patterns of urban light pollution. Moreover, the advantages and limitations of Luojia 1-01 were discussed. The results showed the following: (1) Luojia 1-01 can detect a higher dynamic range and capture the finer spatial details of artificial nighttime light. (2) The averages of the artificial light brightness were different between various land use types. The brightness of the artificial light pollution of airports, streets, and commercial services is high, while dark areas include farmland and rivers. (3) The light pollution patterns of four cities decreased away from the urban core and the total light pollution is highly related to the economic development. Our findings confirm that Luojia 1-01 can be effectively used to investigate artificial light pollution. Some limitations of Luojia 1-01, including its spectral range, radiometric calibration and the effects of clouds and moonlight, should be researched in future studies.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1424-8220 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number GFZ @ kyba @ Serial 1997
Permanent link to this record
 

 
Author Li, X.; Zhao, L.; Li, D.; Xu, H.
Title Mapping Urban Extent Using Luojia 1-01 Nighttime Light Imagery Type Journal Article
Year 2018 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)
Volume (down) 18 Issue 11 Pages
Keywords Instrumentation; Remote Sensing
Abstract Luojia 1-01 satellite, launched on 2 June 2018, provides a new data source of nighttime light at 130 m resolution and shows potential for mapping urban extent. In this paper, using Luojia 1-01 and VIIRS nighttime light imagery, we compared several methods for extracting urban areas, including Human Settlement Index (HSI), Simple Thresholding Segmentation (STS) and SVM supervised classification. According to the accuracy assessment, the HSI method using LJ1-01 data had the best performance in urban extent extraction, which presented the largest Kappa Coefficient value, 0.834, among all the results. For the urban areas extracted by VIIRS based HSI method, the largest Kappa Coefficient value was 0.772. In contrast, the largest Kappa Coefficient values obtained by STS method were 0.79 and 0.7512 respectively when using LJ1-01 and VIIRS data, while for SVM method the values were 0.7829 and 0.7486 when using Landsat-LJ and Landsat-VIIRS composite data respectively. The experimented results demonstrated that the utilization of nighttime light imagery can largely improve the accuracy of urban extent extraction and LJ1-01 data, with a higher resolution and more abundant spatial information, can lead to better identification results than its predecessors.
Address Key Laboratory of the Ministry of Land and Resources for Law Evaluation Engineering, Wuhan 430074, China. xuhuimin1985_2008@163.com
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1424-8220 ISBN Medium
Area Expedition Conference
Notes PMID:30380616 Approved no
Call Number GFZ @ kyba @ Serial 2056
Permanent link to this record
 

 
Author Zhang, G.; Li, L.; Jiang, Y.; Shen, X.; Li, D.
Title On-Orbit Relative Radiometric Calibration of the Night-Time Sensor of the LuoJia1-01 Satellite Type Journal Article
Year 2018 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)
Volume (down) 18 Issue 12 Pages
Keywords Instrumentation; Remote Sensing
Abstract The LuoJia1-01 satellite can acquire high-resolution, high-sensitivity nighttime light data for night remote sensing applications. LuoJia1-01 is equipped with a 4-megapixel CMOS sensor composed of 2048 x 2048 unique detectors that record weak nighttime light on Earth. Owing to minute variations in manufacturing and temporal degradation, each detector's behavior varies when exposed to uniform radiance, resulting in noticeable detector-level errors in the acquired imagery. Radiometric calibration helps to eliminate these detector-level errors. For the nighttime sensor of LuoJia1-01, it is difficult to directly use the nighttime light data to calibrate the detector-level errors, because at night there is no large-area uniform light source. This paper reports an on-orbit radiometric calibration method that uses daytime data to estimate the relative calibration coefficients for each detector in the LuoJia1-01 nighttime sensor, and uses the calibrated data to correct nighttime data. The image sensor has a high dynamic range (HDR) mode, which is optimized for day/night imaging applications. An HDR image can be constructed using low- and high-gain HDR images captured in HDR mode. Hence, a day-to-night radiometric reference transfer model, which uses daytime uniform calibration to calibrate the detector non-uniformity of the nighttime sensor, is herein built for LuoJia1-01. Owing to the lack of calibration equipment on-board LuoJia1-01, the dark current of the nighttime sensor is calibrated by collecting no-light desert images at new moon. The results show that in HDR mode (1) the root mean square of mean for each detector in low-gain (high-gain) images is better than 0.04 (0.07) in digital number (DN) after dark current correction; (2) the DN relationship between low- and high-gain images conforms to the quadratic polynomial mode; (3) streaking metrics are better than 0.2% after relative calibration; and (4) the nighttime sensor has the same relative correction parameters at different exposure times for the same gain parameters.
Address State Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University, Wuhan 430079, China. drli@whu.edu.cn
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1424-8220 ISBN Medium
Area Expedition Conference
Notes PMID:30513817 Approved no
Call Number GFZ @ kyba @ Serial 2125
Permanent link to this record
 

 
Author Bierman, A.; Figueiro, M.G.; Rea, M.S.
Title Measuring and predicting eyelid spectral transmittance Type Journal Article
Year 2011 Publication Journal of Biomedical Optics Abbreviated Journal J Biomed Opt
Volume (down) 16 Issue 6 Pages 067011
Keywords Instrumentation; Human Health
Abstract The purpose of the present study was to objectively quantify the spectral transmittance of the eyelid. Reported here are data acquired using a technique that was developed to provide practical and accurate measurements of eyelid transmittance across the visible portion of the electromagnetic spectrum. The empirical data were analyzed in terms of the absorption and scattering characteristics of the constituents of skin to develop a method for predicting eyelid transmission. Results showed that the eyelid has a much higher optical density at short wavelengths than previously published. The mean +/- standard deviation (s.d.) optical density of the eyelid from 450 to 650 nm was 2.1 +/- 0.3 with an optical density range among subjects of approximately 1.0. The study results indicate that skin pigmentation is poorly correlated with eyelid transmission; eyelid transmission is most affected by wavelength-independent macromolecules in the eyelid as well as its overall thickness.
Address Rensselaer Polytechnic Institute, Lighting Research Center, 21 Union Street, Troy, New York 12180, USA
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1083-3668 ISBN Medium
Area Expedition Conference
Notes PMID:21721832 Approved no
Call Number LoNNe @ kyba @ Serial 1530
Permanent link to this record
 

 
Author Dobler, G.; Ghandehari, M.; Koonin, S.E.; Sharma, M.S.
Title A Hyperspectral Survey of New York City Lighting Technology Type Journal Article
Year 2016 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)
Volume (down) 16 Issue 12 Pages 2047
Keywords Remote Sensing; Instrumentation; Lighting
Abstract Using side-facing observations of the New York City (NYC) skyline, we identify lighting technologies via spectral signatures measured with Visible and Near Infrared (VNIR) hyperspectral imaging. The instrument is a scanning, single slit spectrograph with 872 spectral channels from 0.4-1.0 mu m. With a single scan, we are able to clearly match the detected spectral signatures of 13 templates of known lighting types. However, many of the observed lighting spectra do not match those that have been measured in the laboratory. We identify unknown spectra by segmenting our observations and using Template-Activated Partition (TAP) clustering with a variety of underlying unsupervised clustering methods to generate the first empirically-determined spectral catalog of roughly 40 urban lighting types. We show that, given our vantage point, we are able to determine lighting technology use for both interior and exterior lighting. Finally, we find that the total brightness of our scene shows strong peaks at the 570 nm Na – II , 595 nm Na – II and 818 nm Na – I lines that are common in high pressure sodium lamps, which dominate our observations.
Address NYU Center for Urban Science and Progress, 1 MetroTech Center, Brooklyn, NY 11201, USA. mohit.sharma@nyu.edu
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1424-8220 ISBN Medium
Area Expedition Conference
Notes PMID:27929391 Approved no
Call Number LoNNe @ kyba @ Serial 1567
Permanent link to this record