|   | 
Details
   web
Records
Author Nievas Rosillo, M.
Title Absolute photometry and Night Sky Brightness with all-sky cameras Type Report
Year (up) 2013 Publication e-prints Complutense Abbreviated Journal e-prints Complutense
Volume Issue 24626 Pages
Keywords Instrumentation; skyglow; measurement; modeling
Abstract All-sky cameras have proven to be powerful tools to continuously monitoring the sky in a wide range of fields in both Astrophysics and Meteorology. In this work, we have developed a complete software pipeline to analyze the night CCD images obtained with one of such systems. This let us to study typical parameters used in Astrophysics to characterize the night sky quality, such as the Sky Brightness, the Cloud Coverage and the Atmospheric Extinction, how they evolve over the time and their variability. Using our software, we analyzed a large set of data from AstMon-OT all-sky camera at Teide Observatory. Results from this work have been applied in the support to the spanish CTA site proposal at Izaña, Tenerife and are being discussed within the CTA consortium. A comparison with data from other devices that have been used in site characterization such as the IAC80 telescope is also presented. This comparison is used to validate the results of the analysis of all-sky images. Finally, we test our software with AstMon-UCM and DSLR cameras. Some general recommendations for the use of DSLR cameras are provided.
Address Departamento de Astrofí­sica y Ciencias de la Atmosfera, Universidad Complutense de Madrid, Madrid, Spain
Corporate Author Thesis Master's thesis
Publisher Place of Publication Madrid Editor
Language English Summary Language English Original Title
Series Editor Series Title e-prints Complutense Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number IDA @ john @ Serial 1437
Permanent link to this record
 

 
Author Schnitt, S.; Ruhtz, T.; Fischer, J.; Hölker, F.; Kyba, C.C.M.
Title Temperature stability of the sky quality meter Type Journal Article
Year (up) 2013 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)
Volume 13 Issue 9 Pages 12166-12174
Keywords *Artifacts; Atmosphere/*analysis; Environmental Monitoring/*instrumentation; Equipment Design; Equipment Failure Analysis; Photometry/*instrumentation; Reproducibility of Results; Sensitivity and Specificity; Temperature; *Transducers; Sky Quality Meter; SQM
Abstract The stability of radiance measurements taken by the Sky Quality Meter (SQM)was tested under rapidly changing temperature conditions during exposure to a stable light field in the laboratory. The reported radiance was found to be negatively correlated with temperature, but remained within 7% of the initial reported radiance over a temperature range of -15 degrees C to 35 degrees C, and during temperature changes of -33 degrees C/h and +70 degrees C/h.This is smaller than the manufacturer's quoted unit-to-unit systematic uncertainty of 10%,indicating that the temperature compensation of the SQM is adequate under expected outdoor operating conditions.
Address Institute for Space Sciences, Freie Universitat Berlin, Carl-Heinrich-Becker-Weg 6-10, Berlin 12165, Germany. christopher.kyba@wew.fu-berlin.de
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1424-8220 ISBN Medium
Area Expedition Conference
Notes PMID:24030682; PMCID:PMC3821345 Approved no
Call Number IDA @ john @ Serial 194
Permanent link to this record
 

 
Author Gaston, K.J.
Title Sustainability: A green light for efficiency Type Journal Article
Year (up) 2013 Publication Nature Abbreviated Journal Nature
Volume 497 Issue 7451 Pages 560-561
Keywords Editorial; Animals; Atmosphere/chemistry; Carbon Dioxide/analysis; Circadian Rhythm/physiology; Conservation of Energy Resources/economics/*methods/*trends; Global Warming/prevention & control; Humans; Lighting/*economics/instrumentation/statistics & numerical data/*trends; Public Health
Abstract
Address Environment and Sustainability Institute, University of Exeter, Penryn, UK. k.j.gaston@exeter.ac.uk
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0028-0836 ISBN Medium
Area Expedition Conference
Notes PMID:23719447 Approved no
Call Number LoNNe @ christopher.kyba @ Serial 459
Permanent link to this record
 

 
Author Miller, S.; Straka, W.; Mills, S.; Elvidge, C.; Lee, T.; Solbrig, J.; Walther, A.; Heidinger, A.; Weiss, S.
Title Illuminating the Capabilities of the Suomi National Polar-Orbiting Partnership (NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band Type Journal Article
Year (up) 2013 Publication Remote Sensing Abbreviated Journal Remote Sensing
Volume 5 Issue 12 Pages 6717-6766
Keywords Instrumentation; satellite imagery; nighttime visible/near-infrared; moonlight
Abstract Daytime measurements of reflected sunlight in the visible spectrum have been a staple of Earth-viewing radiometers since the advent of the environmental satellite platform. At night, these same optical-spectrum sensors have traditionally been limited to thermal infrared emission, which contains relatively poor information content for many important weather and climate parameters. These deficiencies have limited our ability to characterize the full diurnal behavior and processes of parameters relevant to improved monitoring, understanding and modeling of weather and climate processes. Visible-spectrum light information does exist during the nighttime hours, originating from a wide variety of sources, but its detection requires specialized technology. Such measurements have existed, in a limited way, on USA Department of Defense satellites, but the Suomi National Polar-orbiting Partnership (NPP) satellite, which carries a new Day/Night Band (DNB) radiometer, offers the first quantitative measurements of nocturnal visible and near-infrared light. Here, we demonstrate the expanded potential for nocturnal low-light visible applications enabled by the DNB. Via a combination of terrestrial and extraterrestrial light sources, such observations are always available—expanding many current existing applications while enabling entirely new capabilities. These novel low-light measurements open doors to a wealth of new interdisciplinary research topics while lighting a pathway toward the optimized design of follow-on satellite based low light visible sensors.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2072-4292 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number LoNNe @ christopher.kyba @ Serial 468
Permanent link to this record
 

 
Author Wahl, F.; Kantermann, T.; Amft, O.
Title How much Light do you get? Estimating Daily Light Exposure using Smartphones Type Conference Article
Year (up) 2014 Publication Proceedings of the 2014 ACM International Symposium on Wearable Computers Abbreviated Journal Proc. of the 2014 ACM International Symposium on Wearable Computers
Volume n/a Issue n/a Pages 43-46
Keywords Instrumentation; light exposure; context inference, light intensity; light intake; circadian clock; circadian rhythm; mobile sensing
Abstract We present an approach to estimate a persons light exposure using smartphones. We used web-sourced weather reports combined with smartphone light sensor data, time of day, and indoor/outdoor information, to estimate illuminance around the user throughout a day. Since light dominates every human’s circadian rhythm and influences the sleep-wake cycle, we developed a smartphone-based system that does not re- quire additional sensors for illuminance estimation. To evaluate our approach, we conducted a free-living study with 12 users, each carrying a smartphone, a head-mounted light reference sensor, and a wrist-worn light sensing device for six consecutive days. Estimated light values were compared to the head-mounted reference, the wrist-worn device and a mean value estimate. Our results show that illuminance could be estimated at less than 20% error for all study participants, outperforming the wrist-worn device. In 9 out of 12 participants the estimation deviated less than 10% from the reference measurements.
Address ACTLab, Chair of Sensor Technology, University of Passau (florian.wahl@uni-passau.de)
Corporate Author Thesis
Publisher ACM Place of Publication Editor
Language English Summary Language English Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number IDA @ john @ Serial 1206
Permanent link to this record