Details
   web
Records
Author Brainard, G.C.; Coyle, W.; Ayers, M.; Kemp, J.; Warfield, B.; Maida, J.; Bowen, C.; Bernecker, C.; Lockley, S.W.; Hanifin, J.P.
Title Solid-state lighting for the International Space Station: Tests of visual performance and melatonin regulation Type Journal Article
Year 2013 Publication (up) Acta Astronautica Abbreviated Journal Acta Astronautica
Volume 92 Issue 1 Pages 21-28
Keywords Human Health; Lighting
Abstract The International Space Station (ISS) uses General Luminaire Assemblies (GLAs) that house fluorescent lamps for illuminating the astronauts' working and living environments. Solid-state light emitting diodes (LEDs) are attractive candidates for replacing the GLAs on the ISS. The advantages of LEDs over conventional fluorescent light sources include lower up-mass, power consumption and heat generation, as well as fewer toxic materials, greater resistance to damage and long lamp life. A prototype Solid-State Lighting Assembly (SSLA) was developed and successfully installed on the ISS. The broad aim of the ongoing work is to test light emitted by prototype SSLAs for supporting astronaut vision and assessing neuroendocrine, circadian, neurobehavioral and sleep effects. Three completed ground-based studies are presented here including experiments on visual performance, color discrimination, and acute plasma melatonin suppression in cohorts of healthy, human subjects under different SSLA light exposure conditions within a high-fidelity replica of the ISS Crew Quarters (CQ). All visual tests were done under indirect daylight at 201 lx, fluorescent room light at 531 lx and 4870 K SSLA light in the CQ at 1266 lx. Visual performance was assessed with numerical verification tests (NVT). NVT data show that there are no significant differences in score (F=0.73, p=0.48) or time (F=0.14, p=0.87) for subjects performing five contrast tests (10%–100%). Color discrimination was assessed with Farnsworth-Munsell 100 Hue tests (FM-100). The FM-100 data showed no significant differences (F=0.01, p=0.99) in color discrimination for indirect daylight, fluorescent room light and 4870 K SSLA light in the CQ. Plasma melatonin suppression data show that there are significant differences (F=29.61, p<0.0001) across the percent change scores of plasma melatonin for five corneal irradiances, ranging from 0 to 405 &#956;W/cm2 of 4870 K SSLA light in the CQ (0–1270 lx). Risk factors for the health and safety of astronauts include disturbed circadian rhythms and altered sleep–wake patterns. These studies will help determine if SSLA lighting can be used both to support astronaut vision and serve as an in-flight countermeasure for circadian desynchrony, sleep disruption and cognitive performance deficits on the ISS.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0094-5765 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number LoNNe @ kyba @ Serial 1533
Permanent link to this record
 

 
Author Hough, W.
Title The development of illumination Type Journal Article
Year 1901 Publication (up) American Anthropologist Abbreviated Journal
Volume 3 Issue 2 Pages 342-352
Keywords History; Society; Lighting
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number GFZ @ kyba @ Serial 2416
Permanent link to this record
 

 
Author Arnold, G.; Mellinger, D.; Markowitz, P.; Burke, M.; Lahar, D.
Title A Win-Win-Win for Municipal Street Lighting: Converting Two-Thirds of Vermont's Street Lights to LED by 2014. Type Journal Article
Year 2012 Publication (up) American Council for an Energy-Efficient Economy. Abbreviated Journal
Volume Issue Pages
Keywords Lighting Systems
Abstract Reducing energy costs and enhancing the nighttime environment with LED street lighting

is by now well understood. However, few municipalities and utilities have successfully taken

advantage of this opportunity to convert their street lighting operations to LEDs. Before a

system-wide conversion of existing street lights can occur, a utility must obtain the large amount

of required capital, identify appropriate LED street light equipment for their applications,

consider changes in utility rate structures, and design effective methods for recovering costs.

Using Vermont as a case study, this paper presents a partnership model among the statewide

energy efficiency utility, the state’s largest electric utilities, and several municipalities. The

model was designed to overcome the challenges to widespread LED street light conversion. By

2014, more than two-thirds of Vermont’s municipal street lights will be upgraded to LED

technology. The conversion will: (1) provide municipalities with better nighttime street lighting

and significant cost savings—at no additional capital expense to the municipalities, (2) deliver

8,000 MWh of cost-effective new savings to the energy efficiency utility, and (3) deliver

financially attractive returns for Vermont’s utilities. This win-win-win model is scalable and

replicable, and is now being considered in Massachusetts and Rhode Island
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number LoNNe @ christopher.kyba @ Serial 446
Permanent link to this record
 

 
Author Stevens, R.G.; Brainard, G.C.; Blask, D.E.; Lockley, S.W.; Motta, M.E.
Title Adverse health effects of nighttime lighting: comments on American Medical Association policy statement Type Journal Article
Year 2013 Publication (up) American Journal of Preventive Medicine Abbreviated Journal Am J Prev Med
Volume 45 Issue 3 Pages 343-346
Keywords American Medical Association; Cell Cycle/physiology; Circadian Rhythm/*physiology; DNA Damage/physiology; *Health Policy; Humans; Lighting/*adverse effects; United States
Abstract The American Medical Association House of Delegates in June of 2012 adopted a policy statement on nighttime lighting and human health. This major policy statement summarizes the scientific evidence that nighttime electric light can disrupt circadian rhythms in humans and documents the rapidly advancing understanding from basic science of how disruption of circadian rhythmicity affects aspects of physiology with direct links to human health, such as cell cycle regulation, DNA damage response, and metabolism. The human evidence is also accumulating, with the strongest epidemiologic support for a link of circadian disruption from light at night to breast cancer. There are practical implications of the basic and epidemiologic science in the form of advancing lighting technologies that better accommodate human circadian rhythmicity.
Address University of Connecticut Health Center, Farmington, Connecticut 06030-6325, USA. bugs@uchc.edu
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0749-3797 ISBN Medium
Area Expedition Conference
Notes PMID:23953362 Approved no
Call Number IDA @ john @ Serial 130
Permanent link to this record
 

 
Author Day, J.; Baker, J.; Schofield, H.; Mathews, F.; Gaston, K.J.
Title Part-night lighting: implications for bat conservation: Part-night lighting and bats Type Journal Article
Year 2015 Publication (up) Animal Conservation Abbreviated Journal Anim Conserv
Volume Issue Pages n/a-n/a
Keywords Animals; Conservation; Lighting
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1367-9430 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number LoNNe @ christopher.kyba @ Serial 1139