Author Liu, X.Y.; Luo, M.R.; Li, H. url  openurl
  Title (up) A study of atmosphere perceptions in a living room Type Journal Article
  Year 2014 Publication Lighting Research and Technology Abbreviated Journal Lighting Research and Technology  
  Volume 47 Issue 5 Pages 581-594  
  Keywords lighting; indoor lighting; perception; Chinese; Dutch; aesthetics  
  Abstract An experiment has been carried out to investigate the effect of lighting on the perception of atmosphere in a living room, using three types of light sources: halogen, fluorescent and LED lamps. In a psychophysical experiment, 29 native Chinese observers assessed eight lighting conditions having different luminances and correlated colour temperatures. For each condition, 71 scales were employed using the categorical judgment method. Factor analysis identified two underlying dimensions: liveliness and cosiness. This agrees with those found by Vogels who used Dutch observers to assess atmosphere perception. Both observer groups also agreed that an increase of luminance would make the room more lively. However, there were also some disagreements such as a higher CCT source would make the room more lively for Chinese observers but less lively for Dutch observers.  
  Address State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou, China  
  Corporate Author Thesis  
  Publisher SAGE Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 310  
Permanent link to this record
 

 
Author Ho, C.Y.; Lin, H.T.; Huang, K.Y. url  doi
openurl 
  Title (up) A Study on Energy Saving and Light Pollution of LED Advertising Signs Type Journal Article
  Year 2011 Publication Applied Mechanics and Materials Abbreviated Journal Amm  
  Volume 121-126 Issue Pages 2979-2984  
  Keywords Advertising Sign; LED; Light Trespass; Luminance Limit; Saving Energy; Vertical Illuminance; *Lighting  
  Abstract Lighting advertising signs not only play an important role in outdoor lighting environment in Taiwan, but also become the main factor of energy consumption in urban areas at night. Light-emitting diode (LED) has been gradually used in advertising signs due to its advantages. However, in order to be conspicuous and legible in the daytime, signs that are excessively bright may result in considerable light pollution and energy waste at nighttime. Therefore, this research aims to measure the luminance of LED signs and traditional internally lighted signs, and analyze the light trespass from each signage. Based on the research results, the energy consumption from a LED full color screen is 12 times more than a traditional internally lighted sign per day. Statistically, all kinds of LED signs are much higher than traditional internally lighted signs in the percentage of excessive brightness and average luminance value. As for the light trespass, since the vertical illuminance on facade facing the signs increases with the increase of the sign area or the decrease of the distance between the sign and the facade, the vertical illuminance on facade facing the signs would exceed the limit of CIE even if the luminance of the signs achieves the standard of CIE in terms of the general conditions in Taiwan. This happens to LED full color screens in particular and thus results in considerable obtrusive light. To sum up, in order to reduce unnecessary energy consumption and improve the nighttime lighting quality for outdoor environment, this research recommends the luminance limitation for light dimming of LED advertising signs should refer to the zoning, time period, and sign area.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1662-7482 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 126  
Permanent link to this record
 

 
Author Park, H.-K.; Gu, J.-H.; Lee, K.-M. url  doi
openurl 
  Title (up) A study on selecting of Light Cutoff Panel depending on the installation condition using the lighting simulation Type Journal Article
  Year 2016 Publication Journal of the Korea Academia-Industrial cooperation Society Abbreviated Journal Journal of the Korea Academia-Industrial cooperation Society  
  Volume 17 Issue 2 Pages 246-251  
  Keywords Lighting; Light cutoff panel; Light pollution; Light trespass; Relux; Security light  
  Abstract The use of security lighting that emits spill light is considered a cause of light trespass problems in the residential areas. Therefore, a cutoff panel was installed as an alternative way to reduce light trespass. On the other hand, it has another problem in that it is less effective and is not good enough for aesthetics and safety. In this study, a light cutoff panel was designed and manufactured to reduce the light trespass, and the structure of a proper light cutoff panel was studied. Using a goniophotometer, the light distribution file (IES file) was extracted and the characteristics of light distribution were analyzed using the RELUX program. The results showed that the reduction of spilt light in the backward direction was decreased significantly for all types of light cutoff panels except the coated globe. In the case of a black powder coated light cutoff panel, the forward light caused by light reflected from the surface of the light cutoff panel was also reduced, which means that the black powder coated light cutoff panel is effective in the performance of light cutoff in the forward and backward directions. In addition, the coated glove increased the spilt light in the forward and backward directions because it reflects the upward light to go down. A 90 % accuracy between the measurement value of light trespass and the expected value of the light trespass was obtained from a simulation.  
  Address National Institute of Environmental Research; mossad61(at)korea.kr  
  Corporate Author Thesis  
  Publisher KoreaScience Place of Publication Editor  
  Language Korean Summary Language English Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1975-4701 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 1448  
Permanent link to this record
 

 
Author Gutierrez-Escolar, A.; Castillo-Martinez, A.; Gomez-Pulido, J.; Gutierrez-Martinez, J.-M.; Stapic, Z.; Medina-Merodio, J.-A. url  doi
openurl 
  Title (up) A Study to Improve the Quality of Street Lighting in Spain Type Journal Article
  Year 2015 Publication Energies Abbreviated Journal Energies  
  Volume 8 Issue 2 Pages 976-994  
  Keywords Energy; Lighting; Planning; Regulation  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1996-1073 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ christopher.kyba @ Serial 1096  
Permanent link to this record
 

 
Author Li, Q.F.; Yang, G.X.; Yu, L.H.; Zhang, H. url  doi
openurl 
  Title (up) A survey of the luminance distribution in the nocturnal environment in Shanghai urban areas and the control of luminance of floodlit buildings Type Journal Article
  Year 2006 Publication Lighting Research & Technology Abbreviated Journal Lighting Research & Technology  
  Volume 38 Issue 3 Pages 185-189  
  Keywords Lighting  
  Abstract A survey of the luminance distribution of the nocturnal environment in Shanghai urban areas, which included 11 locations and 16 buildings, was made. The 11 locations could be categorized as commercial, administration, leisure or residential. The average environmental luminance of these was recorded. The authors identified the effects of excessive exterior lighting. The luminance was measured and subjective appraisals made of 16 buildings. The writers have developed an empirical formula for arriving at the brightness level rating for floodlit buildings and recommended corresponding working ranges of luminance.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1477-1535 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2715  