toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Shang, Y.-M.; Wang, G.-S.; Sliney, D.; Yang, C.-H.; Lee, L.-L. url  doi
openurl 
  Title White light-emitting diodes (LEDs) at domestic lighting levels and retinal injury in a rat model Type Journal Article
  Year 2014 Publication Environmental Health Perspectives Abbreviated Journal Environ Health Perspect  
  Volume (down) 122 Issue 3 Pages 269-276  
  Keywords LED; light emitting diode; lighting; retina; Eye Diseases; blue light; Blue-rich light sources  
  Abstract BACKGROUND: Light-emitting diodes (LEDs) deliver higher levels of blue light to the retina than do conventional domestic light sources. Chronic exposure to high-intensity light (2,000-10,000 lux) has previously been found to result in light-induced retinal injury, but chronic exposure to relatively low-intensity (750 lux) light has not been previously assessed with LEDs in a rodent model. OBJECTIVE: We examined LED-induced retinal neuronal cell damage in the Sprague-Dawley rat using functional, histological, and biochemical measurements. METHODS: We used blue LEDs (460 nm) and full-spectrum white LEDs, coupled with matching compact fluorescent lights, for exposures. Pathological examinations included electroretinogram, hematoxylin and eosin (H&E) staining, immunohistochemistry (IHC), and transmission electron microscopy (TEM). We also measured free radical production in the retina to determine the oxidative stress level. RESULTS: H&E staining and TEM revealed apoptosis and necrosis of photoreceptors, which indicated blue-light induced photochemical injury of the retina. Free radical production in the retina was increased in LED-exposed groups. IHC staining demonstrated that oxidative stress was associated with retinal injury. Although we found serious retinal light injury in LED groups, the compact fluorescent lamp (CFL) groups showed moderate to mild injury. CONCLUSION: Our results raise questions about adverse effects on the retina from chronic exposure to LED light compared with other light sources that have less blue light. Thus, we suggest a precautionary approach with regard to the use of blue-rich “white” LEDs for general lighting. CITATION: Shang YM, Wang GS, Sliney D, Yang CH, Lee LL. 2014. White light-emitting diodes (LEDs) at domestic lighting levels and retinal injury in a rat model. Environ Health Perspect 122:269-276; http://dx.doi.org/10.1289/ehp.1307294.  
  Address Institute of Environmental Health, National Taiwan University, Taipei, Taiwan  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0091-6765 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:24362357; PMCID:PMC3948037 Approved no  
  Call Number IDA @ john @ Serial 324  
Permanent link to this record
 

 
Author Ho, C.Y.; Lin, H.T.; Huang, K.Y. url  doi
openurl 
  Title A Study on Energy Saving and Light Pollution of LED Advertising Signs Type Journal Article
  Year 2011 Publication Applied Mechanics and Materials Abbreviated Journal Amm  
  Volume (down) 121-126 Issue Pages 2979-2984  
  Keywords Advertising Sign; LED; Light Trespass; Luminance Limit; Saving Energy; Vertical Illuminance; *Lighting  
  Abstract Lighting advertising signs not only play an important role in outdoor lighting environment in Taiwan, but also become the main factor of energy consumption in urban areas at night. Light-emitting diode (LED) has been gradually used in advertising signs due to its advantages. However, in order to be conspicuous and legible in the daytime, signs that are excessively bright may result in considerable light pollution and energy waste at nighttime. Therefore, this research aims to measure the luminance of LED signs and traditional internally lighted signs, and analyze the light trespass from each signage. Based on the research results, the energy consumption from a LED full color screen is 12 times more than a traditional internally lighted sign per day. Statistically, all kinds of LED signs are much higher than traditional internally lighted signs in the percentage of excessive brightness and average luminance value. As for the light trespass, since the vertical illuminance on facade facing the signs increases with the increase of the sign area or the decrease of the distance between the sign and the facade, the vertical illuminance on facade facing the signs would exceed the limit of CIE even if the luminance of the signs achieves the standard of CIE in terms of the general conditions in Taiwan. This happens to LED full color screens in particular and thus results in considerable obtrusive light. To sum up, in order to reduce unnecessary energy consumption and improve the nighttime lighting quality for outdoor environment, this research recommends the luminance limitation for light dimming of LED advertising signs should refer to the zoning, time period, and sign area.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1662-7482 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 126  
Permanent link to this record
 

 
Author Luginbuhl, C.B.; Lockwood, G.W.; Davis, D.R.; Pick, K.; Selders, J. url  doi
openurl 
  Title From The Ground Up I: Light Pollution Sources in Flagstaff, Arizona Type Journal Article
  Year 2009 Publication Publications of the Astronomical Society of the Pacific Abbreviated Journal Publ Astron Soc Pac  
  Volume (down) 121 Issue 876 Pages 185-203  
  Keywords light pollution; Flagstaff; Arizona; measurements; lighting policy; public policy  
  Abstract We develop an estimate of the complete outdoor lighting of Flagstaff Arizona, as well as lighting-use densities (lumens per acre) for a number of different land uses. We find a total outdoor light output of 173 million lumens (Mlm) including sports lighting, and 139 Mlm without sports lighting, with an uncertainty of about 7%. The average fraction escaping directly upward from light fixtures is estimated to be 8.3%. After correcting approximately for near-ground blocking described in the accompanying paper by Luginbuhl et al., total uplight is estimated at 17.9 Mlm or 12.2 Mlm with and without sports lighting, respectively. Of these 17.9 Mlm, 33% arise from sports lighting, when it is on; when sports lighting is off, commercial and industrial lighting account for 62% with the remainder dominated by residential (14%) and roadway lighting (12%). We show that the 1989 Flagstaff lighting code that limited total outdoor lighting on new construction has reduced the growth rate of lighting, resulting in a 17% growth in light escaping into the sky from 1989 to 2003, compared to a 43% increase expected if the 1989 code had not been enacted. If all legally nonconforming lighting installed before 1989 were to be brought into compliance with the code, we would expect sky glow in Flagstaff to actually decrease by 36% compared to that in 2003; if all lighting, including residential, could be converted to fully shielded fixtures, sky glow would decrease to about half the current value. The implications for the most effective ways to address sky glow through lighting codes are discussed.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0004-6280 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 246  
Permanent link to this record
 

 
Author Kersavage, K.; Skinner, N.P.; Bullough, J.D.; Garvey, P.M.; Donnell, E.T.; Rea, M.S. url  doi
openurl 
  Title Investigation of flashing and intensity characteristics for vehicle-mounted warning beacons Type Journal Article
  Year 2018 Publication Accident Analysis & Prevention Abbreviated Journal Accident Analysis & Prevention  
  Volume (down) 119 Issue Pages 23-28  
  Keywords Security; Public Safety; Lighting  
  Abstract Reducing the potential for crashes involving front line service workers and passing vehicles is important for increasing worker safety in work zones and similar locations. Flashing yellow warning beacons are often used to protect, delineate, and provide visual information to drivers within and approaching work zones. A nighttime field study using simulated workers, with and without reflective vests, present outside trucks was conducted to evaluate the effects of different warning beacon intensities and flash frequencies. Interactions between intensity and flash frequency were also analyzed. This study determined that intensitiesof 25/2.5 cd and 150/15 cd (peak/trough intensity) provided the farthest detection distances of the simulated worker. Mean detection distances in response to a flash frequency of 1 Hz were not statistically different from those in response to 4 Hz flashing. Simulated workers wearing reflective vests were seen the farthest distances away from the trucks for all combinations of intensity and flash frequency.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0001-4575 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 1950  
Permanent link to this record
 

 
Author Spivey, A. url  doi
openurl 
  Title Light at night and breast cancer risk worldwide Type
  Year 2010 Publication Environmental Health Perspectives Abbreviated Journal Environ Health Perspect  
  Volume (down) 118 Issue 12 Pages a525  
  Keywords Human Health; Breast Neoplasms/epidemiology/*etiology/prevention & control; Female; Humans; Lighting/*adverse effects; Male; Prostatic Neoplasms/epidemiology/*etiology/prevention & control; Risk Factors  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0091-6765 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:21123149; PMCID:PMC3002207 Approved no  
  Call Number LoNNe @ kagoburian @ Serial 813  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: