Details
   web
Records
Author Fotios, S.; Monteiro, A.L.; Uttley, J.
Title Evaluation of pedestrian reassurance gained by higher illuminances in residential streets using the day–dark approach Type Journal Article
Year 2018 Publication (up) Lighting Research & Technology Abbreviated Journal Lighting Research & Technology
Volume in press Issue Pages
Keywords Vision; Psychology; Security
Abstract A field study was conducted to investigate how changes in the illuminance affect pedestrian reassurance when walking after dark in an urban location. The field study was conducted in daytime and after dark in order to employ the day–dark approach to analysis of optimal lighting. The results suggest that minimum illuminance is a better predictor of reassurance than is mean illuminance. For a day–dark difference of 0.5 units on a 6-point response scale, the results suggest a minimum horizontal illuminance of approximately 2.0 lux.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1477-1535 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number GFZ @ kyba @ Serial 2159
Permanent link to this record
 

 
Author Rea, M.S.; Bullough, J.D.; Brons, M.S., J.A.
Title Parking lot lighting based upon predictions of scene brightness and personal safety Type Journal Article
Year 2015 Publication (up) Lighting Research and Technology Abbreviated Journal Lighting Res. & Tech.
Volume 49 Issue 3 Pages 293-304
Keywords Lightingl Security; parking lots; public perceptions; lighting levels
Abstract Providing subjective impressions of security is central to outdoor lighting design. Current parking lot lighting recommendations are based upon photopic illuminances, regardless of spectrum. Scene brightness perception is directly related to impressions of security, and depends upon both light level and spectrum. A provisional model was used to predict scene brightness for three parking lots, each illuminated to different levels by different light sources. Observers judged scene brightness, security and other factors for each lot. The provisional model accurately predicted both scene brightness and security judgements. The lighting associated with the best subjective ratings also had the lowest power density. A design method using ‘brightness illuminance’ is presented, which can lower system costs while maintaining a sense of security by users.
Address Lighting Research Center, Rensselaer Polytechnic Institute, 21 Union Street, Troy, NY 12180, USA. Email: ream(at)rpi.edu
Corporate Author Thesis
Publisher SAGE Place of Publication Editor
Language English Summary Language English Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1477-0938 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number IDA @ john @ Serial 1256
Permanent link to this record
 

 
Author Fotios, S.; Unwin, J.; Farrall, S.
Title Road lighting and pedestrian reassurance after dark: A review Type Journal Article
Year 2015 Publication (up) Lighting Research and Technology Abbreviated Journal Lighting Research and Technology
Volume 47 Issue 4 Pages 449-469
Keywords Security, psychology
Abstract This paper concerns road lighting for pedestrians and how this aids reassurance, their confidence when walking alone after dark. Evidence from past studies that lighting enhances reassurance is supported by the findings of an unfocussed approach that aimed deliberately to avoid focus on lighting or fear, thus to counter the unintended potential for focussed, quantitative methods to lead towards such a finding. Review of the characteristics of lighting suggests an optimum illuminance of 10 lux, of high S/P ratio, and aimed toward the pedestrian and natural elements of the environment, will enhance reassurance. Further research is needed to validate the optimum illuminance, the appropriate metric for characterising lamp spectral power distribution, and the most desirable aims of spatial distribution.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1477-1535 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number LoNNe @ kyba @ Serial 1355
Permanent link to this record
 

 
Author Svechkina, A.; Trop, T.; Portnov, B.A.
Title How Much Lighting is Required to Feel Safe When Walking Through the Streets at Night? Type Journal Article
Year 2020 Publication (up) Sustainability Abbreviated Journal Sustainability
Volume 12 Issue 8 Pages 3133
Keywords Public Safety; Security
Abstract Public space lighting (PSL) is indispensable after the natural dark. However, little is known about how much PSL people actually need to feel sufficiently safe in different real-world urban settings. The present study attempts to answer this question by employing a novel real-time interactive approach, according to which, observers use a specially-designed mobile phone application to assess and report the perceived attributes of street lighting and the feeling of safety (FoS) it generates. To validate the proposed approach, a systematic survey was conducted in three cities in Israel—Tel Aviv-Yafo and Haifa, which lie on the Mediterranean coast, and Be’er Sheba, which lies inland. Additionally, instrumental PSL measurements were performed at the same locations. As the study reveals, the necessary level of illumination required by urban residents to feel safe differs by city and is significantly higher in Be’er Sheba, other factors held equal, in compare to Haifa and Tel Aviv-Yafo. This difference may be attributed to stronger daylight that the residents of the desert city of Be’er Sheba are accustomed to, and, therefore, may prefer stronger nighttime illumination. The difference could also be related to the relatively low socio-economic status and somewhat higher crime rates in the latter city. Findings also show a significant and positive association between FoS and instrumentally measured PSL levels, although this association exhibits diminishing returns. To the best of our knowledge, the present study is the first to use an interactive location- and time-based mobile phone technology, which can potentially provide more accurate and reliable assessments, compared to traditional “pen and paper” survey techniques.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2071-1050 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number GFZ @ kyba @ Serial 2884
Permanent link to this record
 

 
Author Suk, J.Y.; Walter, R.J.
Title New nighttime roadway lighting documentation applied to public safety at night: A case study in San Antonio, Texas Type Journal Article
Year 2019 Publication (up) Sustainable Cities and Society Abbreviated Journal Sustainable Cities and Society
Volume 46 Issue Pages 101459
Keywords Lighting; Public Safety; Security; Planning
Abstract Built environment and public safety professionals view street lighting as an important factor in improving the well-being of the community at night. Extant research that has examined the relationship between street lighting and public safety has found inconclusive or mixed results and has called for more extensive lighting metrics. Using new lighting measurement technologies and geographic information science, this study builds on previous work to demonstrate new metrics to consider when evaluating public safety, specifically crime and traffic accidents. Downtown San Antonio, Texas is used as a case study to explore illuminance levels on roadways and the driver’s eye, and how these metrics can be used to understand the lighting characteristics of where crime and traffic accidents occur. The findings indicate that the central downtown district in San Antonio has higher illuminance levels than the existing roadway lighting guidelines while the residential downtown neighborhoods have insufficient light levels. Statistical analysis reveals that roadway illuminance levels are higher in areas where no crime occurred and driver’s eye illuminance levels are lower in areas with no traffic accidents. The findings prove the usefulness of new lighting documentation techniques and support the importance of considering illuminance metrics when assessing crime and traffic accidents at night.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2210-6707 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number GFZ @ kyba @ Serial 2191
Permanent link to this record