Author Chen, H.; Sun, C.; Chen, X.; Chiang, K.; Xiong, X. url  doi
openurl 
  Title On-orbit calibration and performance of S-NPP VIIRS DNB Type Conference Article
  Year 2016 Publication Proc. SPIE 9881, Earth Observing Missions and Sensors: Development, Implementation, and Characterization IV, 98812B (May 2, 2016) Abbreviated Journal Proc. SPIE 9881  
  Volume Issue Pages  
  Keywords Remote Sensing; VIIRS, Suomi; VIIRS DNB; day-night band; calibration; Land Science Investigator-led Processing Systems; SIPS; Orbital dynamics; Sensors; Stray light; Contamination; Diffusers; Earth sciences; Equipment and services  
  Abstract The S-NPP VIIRS instrument has successfully operated since its launch in October 2011. The VIIRS Day-Night Band (DNB) is a panchromatic channel covering wavelengths from 0.5 to 0.9 μm that is capable of observing Earth scenes during both day and nighttime orbits at a spatial resolution of 750 m. To cover the large dynamic range, the DNB operates at low, mid, or high gain stages, and it uses an onboard solar diffuser (SD) for its low gain stage calibration. The SD observations also provide a means to compute gain ratios of low-to-mid and mid-to-high gain stages. This paper describes the DNB on-orbit calibration methodologies used by the VIIRS Characterization Support Team (VCST) in supporting the NASA earth science community with consistent VIIRS sensor data records (SDRs) made available by the Land Science Investigator-led Processing Systems (SIPS). It provides an assessment and update of DNB on-orbit performance, including the SD degradation in the DNB spectral range, detector gain and gain ratio trending, stray light contamination and its correction. Also presented in this paper are performance validations based on earth scenes and lunar observations.  
  Address Science Systems and Applications, Inc.  
  Corporate Author Thesis  
  Publisher SPIE Place of Publication Editor  
  Language English Summary Language English Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number (up) IDA @ john @ Serial 1473  
Permanent link to this record
 

 
Author Allik, T.; Ramboyong, L.; Roberts, M.; Walters, M.; Soyka, T.; Dixon, R.; Cho, J. url  doi
openurl 
  Title Enhanced oil spill detection sensors in low-light environments Type Conference Article
  Year 2016 Publication Proc. SPIE 9827, Ocean Sensing and Monitoring VIII, 98270B (May 17, 2016) Abbreviated Journal Proc. SPIE 9827  
  Volume Issue Pages  
  Keywords Instrumentation; Sensors; Cameras; Long wavelength infrared; Short wave infrared radiation; Spectroscopy; Calibration; Remote sensing; Water; Near infrared; Night vision  
  Abstract Although advances have been made in oil spill remote detection, many electro-optic sensors do not provide real-time images, do not work well under degraded visual environments, nor provide a measure of extreme oil thickness in marine environments. A joint program now exists between BSEE and NVESD that addresses these capability gaps in remote sensing of oil spills. Laboratory experiments, calibration techniques, and field tests were performed at Fort Belvoir, Virginia; Santa Barbara, California; and the Ohmsett Test Facility in Leonardo, New Jersey. Weathered crude oils were studied spectroscopically and characterized with LWIR, and low-light-level visible/NIR, and SWIR cameras. We designed and fabricated an oil emulsion thickness calibration cell for spectroscopic analysis and ground truth, field measurements. Digital night vision cameras provided real-time, wide-dynamic-range imagery, and were able to detect and recognize oil from full sun to partial moon light. The LWIR camera provided quantitative oil analysis (identification) for >1 mm thick crude oils both day and night. Two filtered, co-registered, SWIR cameras were used to determine whether oil thickness could be measured in real time. Spectroscopic results revealed that oil emulsions vary with location and weathered state and some oils (e.g., ANS and Santa Barbara seeps) do not show the spectral rich features from archived Deep Water Horizon hyperspectral data. Multi-sensor imagery collected during the 2015 USCG Airborne Oil Spill Remote Sensing and Reporting Exercise and the design of a compact, multiband imager are discussed.  
  Address Active EO Inc.  
  Corporate Author Thesis  
  Publisher SPIE Place of Publication Editor  
  Language English Summary Language English Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number (up) IDA @ john @ Serial 1475  
Permanent link to this record
 

 
Author Bará, S.; Tapia, C.; Zamorano, J. url  doi
openurl 
  Title Absolute Radiometric Calibration of TESS-W and SQM Night Sky Brightness Sensors Type Journal Article
  Year 2019 Publication Sensors Abbreviated Journal Sensors  
  Volume 19 Issue 6 Pages 1336  
  Keywords Instrumentation; calibration; SQM; TESS; photometer; sky brightness  
  Abstract We develop a general optical model and describe the absolute radiometric calibration of the readings provided by two widely-used night sky brightness sensors based on irradiance-to-frequency conversion. The calibration involves the precise determination of the overall spectral sensitivity of the devices and also the constant G relating the output frequency of the light-to-frequency converter chip to the actual band-weighted and field-of-view averaged spectral radiance incident on the detector (brightness). From these parameters, we show how to define a rigorous astronomical absolute photometric system in which the sensor measurements can be reported in units of magnitudes per square arcsecond with precise physical meaning.  
  Address Departmento Física Aplicada, Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Galicia, Spain; salva.bara(at)usc.es  
  Corporate Author Thesis  
  Publisher MDPI Place of Publication Editor  
  Language English Summary Language English Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number (up) IDA @ john @ Serial 2263  
Permanent link to this record
 

 
Author Cinzano, P. url  openurl
  Title Night Sky Photometry with Sky Quality Meter Type Journal Article
  Year 2005 Publication Technical Report 9, ISTIL. V1.4. Abbreviated Journal  
  Volume Issue Pages  
  Keywords Instrumentation; light pollution; night sky brightness; photometry; instruments; calibration  
  Abstract Sky Quality Meter, a low cost and pocket size night sky brightness photometer, opens to the general public the possibility to quantify the quality of the night sky. Expecting a large diffusion of measurements taken with this instrument, I tested and characterized it. I analyzed with synthetic photometry and laboratory measurements the relationship between the SQM photometrical system and the main systems used in light pollution studies. I evaluated the conversion factors to Johnson’s B and V bands, CIE photopic and CIE scotopic responses for typical spectra and the spectral mismatch correction factors when specific filters are added.  
  Address Dipartimento di Astronomia, Vicolo dell’Osservatorio 2, I-35100 Padova, Italy; cinzano(at)lplab.it  
  Corporate Author Thesis  
  Publisher ISTIL Place of Publication Editor  
  Language English Summary Language English Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number (up) LoNNe @ christopher.kyba @ Serial 473  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: