toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author (up) Aulsebrook, A.E.; Jones, T.M.; Mulder, R.A.; Lesku, J.A. url  doi
openurl 
  Title Impacts of artificial light at night on sleep: A review and prospectus Type Journal Article
  Year 2018 Publication Journal of Experimental Zoology. Part A, Ecological and Integrative Physiology Abbreviated Journal J Exp Zool A Ecol Integr Physiol  
  Volume 329 Issue 8-9 Pages 409-418  
  Keywords Review; Animals; Health  
  Abstract Natural cycles of light and darkness govern the timing of most aspects of animal behavior and physiology. Artificial light at night (ALAN)-a recent and pervasive form of pollution-can mask natural photoperiodic cues and interfere with biological rhythms. One such rhythm vulnerable to perturbation is the sleep-wake cycle. ALAN may greatly influence sleep in humans and wildlife, particularly in animals that sleep predominantly at night. There has been some recent evidence for impacts of ALAN on sleep, but critical questions remain. Some of these can be addressed by adopting approaches already entrenched in sleep research. In this paper, we review the current evidence for impacts of ALAN on sleep, highlight gaps in our understanding, and suggest opportunities for future research.  
  Address La Trobe University, School of Life Sciences, Melbourne, Victoria, Australia  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2471-5638 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:29869374 Approved no  
  Call Number GFZ @ kyba @ Serial 1933  
Permanent link to this record
 

 
Author (up) Babadi, S.; Ramirez-Inguiez, R.; Boutaleb, T.; Mallick, T. url  doi
openurl 
  Title Producing uniform illumination within a rectangular area by using a nonimaging optic Type Journal Article
  Year 2018 Publication Applied Optics Abbreviated Journal Appl. Opt.  
  Volume 57 Issue 31 Pages 9357  
  Keywords Lighting  
  Abstract This paper proposes a new design method to create a novel optical element to generate uniform illumination within a rectangular area. Based on this model, an illuminated area is irradiated by two sets of rays; the first one irradiates the target plane after refraction from the top section of the lens, and the second one irradiates from the reflection at the side profile of the lens and then from refraction at the top part of the lens. The results show that a uniformity of over 90% can be achieved.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1559-128X ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2046  
Permanent link to this record
 

 
Author (up) Babaii, A., Adib-Hajbaghery, M., & Hajibagheri, A. doi  openurl
  Title Effect of Using Eye Mask on Sleep Quality in Cardiac Patients: A Randomized Controlled Trial. Type Journal Article
  Year 2015 Publication Nursing and Midwifery Studies Abbreviated Journal  
  Volume 4 Issue 4 Pages  
  Keywords Human Health  
  Abstract BACKGROUND:

Patients in coronary care unit are at risk of sleep deprivation. Sleep deprivation can be associated with increased blood pressure and heart rate, raising the risk of developing cardiovascular problems among patients hospitalized in coronary care unit.

OBJECTIVES:

This study was carried out to examine the effect of eye mask on sleep quality in cardiac patients.

PATIENTS AND METHODS:

In this randomized controlled trial, 60 patients who met the inclusion criteria were selected using a convenient sampling method and randomly allocated into the experimental and control groups. Patients in the control group received routine care. However, in the experimental group, patients received routine care and eye mask for three subsequent nights. In the both groups, the sleep quality was assessed using the Pittsburgh sleep quality index. Data were analyzed by the chi-square test, independent samples t-test, Mann-Whitney U, and Wilcoxon signed-rank tests.

RESULTS:

After the study, the median scores of the subjective sleep quality, the sleep latency, the sleep duration, the habitual sleep efficiency, and the sleep disturbances domains, as well as the median score of overall Pittsburgh sleep quality index in the experimental group were significantly lower than those in the control group (P < 0.05). However, no significant differences were observed between the two groups in terms of the use of sleep medications and the daytime dysfunction domains (P > 0.05).

CONCLUSIONS:

Using eye mask can significantly improve the sleep quality in cardiac patients. Therefore, nurses are recommended to use eye mask in combination with current treatments for improving patients' sleep quality.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ intern @ Serial 2303  
Permanent link to this record
 

 
Author (up) Baddiley, C. url  doi
openurl 
  Title Light pollution modelling, and measurements at Malvern Hills AONB, of county conversion to blue rich LEDs Type Journal Article
  Year 2018 Publication Journal of Quantitative Spectroscopy and Radiative Transfer Abbreviated Journal Journal of Quantitative Spectroscopy and Radiative Transfer  
  Volume 219 Issue Pages 142-173  
  Keywords Skyglow  
  Abstract The introduction of blue rich colour, Correlated-Colour-Temperature (CCT) 6000K road lighting could increase skyglow significantly compared with CCT 3000K types, if the blue content reaches the sky.

Highways England have a policy for lighting specification on motorways advised by the author's work. This is a categorised environmental impact point system of summed brightness as a function of angle from vertically down to the cut off angle; but with no CCT limitation.

Modelling was done for Malvern-Hills Area-of-Outstanding-Natural-Beauty (MHAONB), for the nighttime environmental impact of the LED replacement of Low-Pressure-Sodium throughout Herefordshire. The study was extended to include High-Pressure-Sodium and to LEDs at several CCTs, for the same Photopic ground illuminance.

Dark-Sky-Survey geographic location results for the MHAONB (2012) are described. Near-Zenith sky brightness photometry became continuous from 2016 at 2 minute intervals in all weathers, not just clear nights, with a networked calibrated Unihedron Lensed Sky Quality Meter (LSQM). Samples were also taken of all-sky camera images, corrected for vignetting and near-Zenith calibrated with the LSQM, to study weather effects, Milky Way contribution, and Herefordshire lighting conversion to blue-rich LEDs (2013-15), compared with the less converted Severn valley direction.

Time-plots and histogram analysis showed a small reduction in brightness (2012-2018), 0.1 mag.arcsec−2. Most variation is from increased sampling of distant cloud cover effects. Mist or low cloud on the horizon obscures light sources beyond reducing local skyglow, while high cloud reflects, increasing clear sky brightness. The Milky Way is critically 20% above background. Darkest periods near Zenith reach 21.1 mag.arcsec−2, to 21.2 after rain or surrounding low-cloud or poor-visibility. Clear-sky brightness decreases into early hours (∼0.03 mag.arcsec−2/hr); dimming effects were not seen.

The Zenith brightness is still set by distant cities, while towards the horizon, commercial and private uncontrolled non-directional LED lighting is increasing, negating the improvements in road lighting.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0022-4073 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 1914  
Permanent link to this record
 

 
Author (up) Bagan, H.; Borjigin, H.; Yamagata, Y. url  doi
openurl 
  Title Assessing nighttime lights for mapping the urban areas of 50 cities across the globe Type Journal Article
  Year 2018 Publication Environment and Planning B: Urban Analytics and City Science Abbreviated Journal Environment and Planning B: Urban Analytics and City Science  
  Volume Issue Pages 2399808317752926  
  Keywords Remote Sensing  
  Abstract Nighttime data from the Defense Meteorological Satellite Program Operational Linescan System have been widely used to map urban/built-up areas (hereafter referred to as “built-up area”), but to date there has not been a geographically comprehensive evaluation of the effectiveness of using nighttime lights data to map urban areas. We created accurate, convenient, and scalable grid cells based on Defense Meteorological Satellite Program/Operational Linescan System nighttime light pixels. We then calculated the density of Landsat-derived built-up areas within each grid cell. We explored the relationship between Defense Meteorological Satellite Program/Operational Linescan System nighttime lights data and the density of built-up areas to assess the utility of nighttime lights for mapping urban areas in 50 cities across the globe. We found that the brightness of nighttime lights was only in moderate agreement with the density of built-up areas; moreover, correlations between nighttime lights and Landsat-derived built-up areas were weak. Even in relatively sparsely populated urban regions (where the density of the built-up area is less than 20%), the highest correlation coefficient (R2) was only 0.4. Furthermore, nighttime lights showed lighted areas that extended beyond the area of large cities, and nighttime lights reduced the area of small cities. The results suggest that it is difficult to use the regression model to calibrate the Defense Meteorological Satellite Program/Operational Linescan System nighttime lights to fit urban built up areas.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2399-8083 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @; GFZ @ kyba @ Serial 1795  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: