toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Ciocca, M.; Wang, J. url  doi
openurl 
  Title By the light of the silvery Moon: fact and fiction Type Journal Article
  Year 2013 Publication Physics Education Abbreviated Journal Phys. Educ.  
  Volume 48 Issue 3 Pages 360-367  
  Keywords (down) Vision; moonlight; Purkinje effect; Purkinje shift; mesopic  
  Abstract Is moonlight 'silver' or 'cold'? In this paper we discuss the interesting combination of factors that contribute to the common descriptions of moonlight. Sunlight is reflected from the lunar surface and red-shifted. When traversing the atmosphere, moonlight is further depleted of short wavelength content by Rayleigh scattering. We measured the spectra of the moonlight to show these effects and compared them with sunlight. All measurements, including spectral reflectance, suggest that moonlight is redder than sunlight. The silvery Moon is just an illusion due to the properties and behaviour of our own eyes, including the responses of rods and cones and the physiological perceptive phenomenon called Purkinje shift.  
  Address Eastern Kentucky University, Richmond, KY, USA E-mail: marco.ciocca(at)eku.edu  
  Corporate Author Thesis  
  Publisher IOP Place of Publication Editor  
  Language English Summary Language English Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0031-9120 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 2227  
Permanent link to this record
 

 
Author Skinner, N., & Bullough, J. doi  openurl
  Title Influence of LED Spectral Characteristics on Glare Recovery Type Journal Article
  Year 2019 Publication SAE Technical Paper 2019-01-0845 Abbreviated Journal  
  Volume Issue Pages  
  Keywords (down) Vision; Lighting; Public Safety  
  Abstract Headlight glare is a major concern of the driving public. In the past couple of years there have been concerns expressed about the use of light emitting diode (LED) lighting technologies and possible impacts LEDs may have on people, including circadian disruption, retinal hazards, and glare. Under typical use cases, vehicle headlight exposures are insufficient to cause circadian disruption or retinal damage, but can result in disability and discomfort glare, as well as glare recovery. In general, white LEDs used for illumination have greater short-wavelength content than halogen lamps used in many headlights, and short wavelengths have been implicated in visual discomfort from bright lights at night. Previous literature is inconsistent regarding whether the spectral (color) content of a glare source affects the amount of recovery time needed to see objects, following exposure to a bright light such as a vehicle headlight. Warm and cool white LEDs were used as glare sources in the present study. They were energized and exposed to study participants at one of two illuminances (low, high) for either 3 or 6 seconds, after which participants were asked to identify the orientation of a Landolt ring target located on a display screen behind the glare source. Identification times were unaffected by the spectral content of the LED, but were correlated with the “dosage” of light from the glare sources, defined as the product of illuminance and duration. Although cool white LEDs will tend to be judged as creating more discomfort than warm white LEDs, they do not result in longer glare recovery times under the range of conditions used in this study.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ intern @ Serial 2299  
Permanent link to this record
 

 
Author S Fotios, J Uttley url  doi
openurl 
  Title Illuminance required to detect a pavement obstacle of critical size Type Journal Article
  Year 2018 Publication Lighting Research & Technology Abbreviated Journal  
  Volume 50 Issue Pages 390-404  
  Keywords (down) Vision; Lighting  
  Abstract This paper investigates the illuminance needed to detect trip hazards for pedestrians walking after dark. In previous work, it was assumed that the critical obstacle height is 25 mm: further review of accident data and foot clearance data suggests instead that 10 mm is the critical height. Eye tracking records suggest a tendency for obstacles to be detected approximately 3.4 m ahead. Interpretation of obstacle detection data suggests horizontal photopic illuminances of up to 0.9 lux are required for peripheral detection of a 10 mm obstacle 3.4 m ahead, according to the scotopic/photopic ratio of the lighting and the age of the observer.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1765  
Permanent link to this record
 

 
Author Preciado, O.; Manzano, E. url  doi
openurl 
  Title Spectral characteristics of road surfaces and eye transmittance: Effects on energy efficiency of road lighting at mesopic levels Type Journal Article
  Year 2017 Publication Lighting Research & Technology Abbreviated Journal Lighting Research & Technology  
  Volume Issue Pages 147715351771822  
  Keywords (down) Vision; Lighting  
  Abstract In 2010, the CIE published a recommended system for mesopic photometry based on visual performance. According to this system, scenes illuminated at mesopic levels with light sources of high S/P ratio, will produce better visual performance than those illuminated with light sources of a lower S/P ratio at equal photopic luminance. However, there could be other factors affected by SPD that, when quantified, could lead to a contradictory final effect. The scope of this paper was to evaluate how road lighting is affected by the spectral road surface reflectance and by the human eye transmittance as people get older. Our results suggest that the benefits of considering the mesopic vision effect for light sources with high S/P ratios are totally counteracted by the other two effects at mesopic luminances between 0.75 cd/m2 and 1.73 cd/m2 for people between 20 and 60 years of age, depending on the light source and the age of observers.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1477-1535 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 1862  
Permanent link to this record
 

 
Author Fotios, S.; Yao, Q. url  doi
openurl 
  Title The association between correlated colour temperature and scotopic/photopic ratio Type Journal Article
  Year 2018 Publication Lighting Research & Technology Abbreviated Journal Lighting Research & Technology  
  Volume 35 Issue 10 Pages 1365-1374  
  Keywords (down) Vision; Lighting  
  Abstract The scotopic/photopic ratio (S/P) is a parameter that may be considered in the design of road lighting. This paper compares the S/P ratio and correlated colour temperature (CCT) for 297 light source spectra identified in IES Technical Memorandum TM-30-15 to test the assumption that higher S/P ratios demand higher CCTs. The results suggest that, for a given lamp type, there is a strong association between S/P ratio and CCT, and hence that for a given CCT only a small variation in S/P ratio is available. However, the results also suggest that a larger variation in S/P ratio is possible if the lighting designer is able to consider a change in lamp type.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1477-1535 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 1954  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: