Author Elejoste, P.; Angulo, I.; Perallos, A.; Chertudi, A.; Zuazola, I.J.G.; Moreno, A.; Azpilicueta, L.; Astrain, J.J.; Falcone, F.; Villadangos, J. url  doi
openurl 
  Title An easy to deploy street light control system based on wireless communication and LED technology Type Journal Article
  Year 2013 Publication Sensors (Basel, Switzerland) Abbreviated Journal (down) Sensors (Basel)  
  Volume 13 Issue 5 Pages 6492-6523  
  Keywords Lighting  
  Abstract This paper presents an intelligent streetlight management system based on LED lamps, designed to facilitate its deployment in existing facilities. The proposed approach, which is based on wireless communication technologies, will minimize the cost of investment of traditional wired systems, which always need civil engineering for burying of cable underground and consequently are more expensive than if the connection of the different nodes is made over the air. The deployed solution will be aware of their surrounding's environmental conditions, a fact that will be approached for the system intelligence in order to learn, and later, apply dynamic rules. The knowledge of real time illumination needs, in terms of instant use of the street in which it is installed, will also feed our system, with the objective of providing tangible solutions to reduce energy consumption according to the contextual needs, an exact calculation of energy consumption and reliable mechanisms for preventive maintenance of facilities.  
  Address Deusto Institute of Technology (DeustoTech), University of Deusto, Bilbao 48007, Spain. perallos@deusto.es  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:23681092; PMCID:PMC3690067 Approved no  
  Call Number LoNNe @ kagoburian @ Serial 631  
Permanent link to this record
 

 
Author Dobler, G.; Ghandehari, M.; Koonin, S.E.; Sharma, M.S. url  doi
openurl 
  Title A Hyperspectral Survey of New York City Lighting Technology Type Journal Article
  Year 2016 Publication Sensors (Basel, Switzerland) Abbreviated Journal (down) Sensors (Basel)  
  Volume 16 Issue 12 Pages 2047  
  Keywords Remote Sensing; Instrumentation; Lighting  
  Abstract Using side-facing observations of the New York City (NYC) skyline, we identify lighting technologies via spectral signatures measured with Visible and Near Infrared (VNIR) hyperspectral imaging. The instrument is a scanning, single slit spectrograph with 872 spectral channels from 0.4-1.0 mu m. With a single scan, we are able to clearly match the detected spectral signatures of 13 templates of known lighting types. However, many of the observed lighting spectra do not match those that have been measured in the laboratory. We identify unknown spectra by segmenting our observations and using Template-Activated Partition (TAP) clustering with a variety of underlying unsupervised clustering methods to generate the first empirically-determined spectral catalog of roughly 40 urban lighting types. We show that, given our vantage point, we are able to determine lighting technology use for both interior and exterior lighting. Finally, we find that the total brightness of our scene shows strong peaks at the 570 nm Na – II , 595 nm Na – II and 818 nm Na – I lines that are common in high pressure sodium lamps, which dominate our observations.  
  Address NYU Center for Urban Science and Progress, 1 MetroTech Center, Brooklyn, NY 11201, USA. mohit.sharma@nyu.edu  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:27929391 Approved no  
  Call Number LoNNe @ kyba @ Serial 1567  
Permanent link to this record
 

 
Author Li, X.; Zhao, L.; Li, D.; Xu, H. url  doi
openurl 
  Title Mapping Urban Extent Using Luojia 1-01 Nighttime Light Imagery Type Journal Article
  Year 2018 Publication Sensors (Basel, Switzerland) Abbreviated Journal (down) Sensors (Basel)  
  Volume 18 Issue 11 Pages  
  Keywords Instrumentation; Remote Sensing  
  Abstract Luojia 1-01 satellite, launched on 2 June 2018, provides a new data source of nighttime light at 130 m resolution and shows potential for mapping urban extent. In this paper, using Luojia 1-01 and VIIRS nighttime light imagery, we compared several methods for extracting urban areas, including Human Settlement Index (HSI), Simple Thresholding Segmentation (STS) and SVM supervised classification. According to the accuracy assessment, the HSI method using LJ1-01 data had the best performance in urban extent extraction, which presented the largest Kappa Coefficient value, 0.834, among all the results. For the urban areas extracted by VIIRS based HSI method, the largest Kappa Coefficient value was 0.772. In contrast, the largest Kappa Coefficient values obtained by STS method were 0.79 and 0.7512 respectively when using LJ1-01 and VIIRS data, while for SVM method the values were 0.7829 and 0.7486 when using Landsat-LJ and Landsat-VIIRS composite data respectively. The experimented results demonstrated that the utilization of nighttime light imagery can largely improve the accuracy of urban extent extraction and LJ1-01 data, with a higher resolution and more abundant spatial information, can lead to better identification results than its predecessors.  
  Address Key Laboratory of the Ministry of Land and Resources for Law Evaluation Engineering, Wuhan 430074, China. xuhuimin1985_2008@163.com  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:30380616 Approved no  
  Call Number GFZ @ kyba @ Serial 2056  
Permanent link to this record
 

 
Author Zhang, G.; Li, L.; Jiang, Y.; Shen, X.; Li, D. url  doi
openurl 
  Title On-Orbit Relative Radiometric Calibration of the Night-Time Sensor of the LuoJia1-01 Satellite Type Journal Article
  Year 2018 Publication Sensors (Basel, Switzerland) Abbreviated Journal (down) Sensors (Basel)  
  Volume 18 Issue 12 Pages  
  Keywords Instrumentation; Remote Sensing  
  Abstract The LuoJia1-01 satellite can acquire high-resolution, high-sensitivity nighttime light data for night remote sensing applications. LuoJia1-01 is equipped with a 4-megapixel CMOS sensor composed of 2048 x 2048 unique detectors that record weak nighttime light on Earth. Owing to minute variations in manufacturing and temporal degradation, each detector's behavior varies when exposed to uniform radiance, resulting in noticeable detector-level errors in the acquired imagery. Radiometric calibration helps to eliminate these detector-level errors. For the nighttime sensor of LuoJia1-01, it is difficult to directly use the nighttime light data to calibrate the detector-level errors, because at night there is no large-area uniform light source. This paper reports an on-orbit radiometric calibration method that uses daytime data to estimate the relative calibration coefficients for each detector in the LuoJia1-01 nighttime sensor, and uses the calibrated data to correct nighttime data. The image sensor has a high dynamic range (HDR) mode, which is optimized for day/night imaging applications. An HDR image can be constructed using low- and high-gain HDR images captured in HDR mode. Hence, a day-to-night radiometric reference transfer model, which uses daytime uniform calibration to calibrate the detector non-uniformity of the nighttime sensor, is herein built for LuoJia1-01. Owing to the lack of calibration equipment on-board LuoJia1-01, the dark current of the nighttime sensor is calibrated by collecting no-light desert images at new moon. The results show that in HDR mode (1) the root mean square of mean for each detector in low-gain (high-gain) images is better than 0.04 (0.07) in digital number (DN) after dark current correction; (2) the DN relationship between low- and high-gain images conforms to the quadratic polynomial mode; (3) streaking metrics are better than 0.2% after relative calibration; and (4) the nighttime sensor has the same relative correction parameters at different exposure times for the same gain parameters.  
  Address State Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University, Wuhan 430079, China. drli@whu.edu.cn  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:30513817 Approved no  
  Call Number GFZ @ kyba @ Serial 2125  
Permanent link to this record
 

 
Author Zhang, K.; Zhong, X.; Zhang, G.; Li, D.; Su, Z.; Meng, Y.; Jiang, Y. url  doi
openurl 
  Title Thermal Stability Optimization of the Luojia 1-01 Nighttime Light Remote-Sensing Camera's Principal Distance Type Journal Article
  Year 2019 Publication Sensors (Basel, Switzerland) Abbreviated Journal (down) Sensors (Basel)  
  Volume 19 Issue 5 Pages 990  
  Keywords Instrumentation; Luojia 1-01; nighttime light remote-sensing camera; principal distance; optical-passive athermal design; thermal stability  
  Abstract The instability of the principal distance of the nighttime light remote-sensing camera of the Luojia 1-01 satellite directly affects the geometric accuracy of images, consequently affecting the results of analysis of nighttime light remote-sensing data. Based on the theory of optical passive athermal design, a mathematical model of optical-passive athermal design for principal distance stabilization is established. Positive and negative lenses of different materials and the mechanical structures of different materials are matched to optimize the optical system. According to the index requirements of the Luojia 1-01 camera, an image-telecentric optical system was designed under the guidance of the established mathematical model. In the temperature range of -20 degrees C to +60 degrees C, the principal distance of the system changes from -0.01 mum to +0.28 mum. After on-orbit testing, the geometric accuracy of the designed nighttime light remote-sensing camera is better than 0.20 pixels and less than index requirement of 0.3 pixels, which indicating that the principal distance maintains good stability on-orbit and meets the application requirements of nighttime light remote sensing.  
  Address School of Remote Sensing and Information Engineering, Wuhan University, Wuhan 430079, China. jiangyh@whu.edu.cn  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:30813556 Approved no  
  Call Number GFZ @ kyba @ Serial 2238  