Details
   web
Records
Author Schnitt, S.; Ruhtz, T.; Fischer, J.; Hölker, F.; Kyba, C.C.M.
Title Temperature stability of the sky quality meter Type Journal Article
Year 2013 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)
Volume 13 Issue 9 Pages 12166-12174
Keywords *Artifacts; Atmosphere/*analysis; Environmental Monitoring/*instrumentation; Equipment Design; Equipment Failure Analysis; Photometry/*instrumentation; Reproducibility of Results; Sensitivity and Specificity; Temperature; *Transducers; Sky Quality Meter; SQM
Abstract The stability of radiance measurements taken by the Sky Quality Meter (SQM)was tested under rapidly changing temperature conditions during exposure to a stable light field in the laboratory. The reported radiance was found to be negatively correlated with temperature, but remained within 7% of the initial reported radiance over a temperature range of -15 degrees C to 35 degrees C, and during temperature changes of -33 degrees C/h and +70 degrees C/h.This is smaller than the manufacturer's quoted unit-to-unit systematic uncertainty of 10%,indicating that the temperature compensation of the SQM is adequate under expected outdoor operating conditions.
Address Institute for Space Sciences, Freie Universitat Berlin, Carl-Heinrich-Becker-Weg 6-10, Berlin 12165, Germany. christopher.kyba@wew.fu-berlin.de
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title (up)
Series Volume Series Issue Edition
ISSN 1424-8220 ISBN Medium
Area Expedition Conference
Notes PMID:24030682; PMCID:PMC3821345 Approved no
Call Number IDA @ john @ Serial 194
Permanent link to this record
 

 
Author Aceituno, J.; Sánchez, S.F.; Aceituno, F.J.; Galadí-Enríquez, D.; Negro, J.J.; Soriguer, R.C.; Gomez, G.S.
Title An All-Sky Transmission Monitor: ASTMON Type Journal Article
Year 2011 Publication Publications of the Astronomical Society of the Pacific Abbreviated Journal Publications of the Astronomical Society of the Pacific
Volume 123 Issue 907 Pages 1076-1086
Keywords monitoring; light at night; light pollution; skyglow
Abstract We present here the All-Sky Transmission Monitor (ASTMON), designed to perform a continuous monitoring of the surface brightness of the complete night sky in several bands. The data acquired are used to derive, in addition, a subsequent map of the multiband atmospheric extinction at any location in the sky and a map of the cloud coverage. The instrument has been manufactured to withstand extreme weather conditions and to remain operative. Designed to be fully robotic, it is ideal to be installed outdoors as a permanent monitoring station. The preliminary results based on two of the currently operative units (at Doñana National Park, Huelva, and at the Calar Alto Observatory, Almería, Spain) are presented here. The parameters derived using ASTMON are in good agreement with those previously reported, which illustrates the validity of the design and the accuracy of the manufacturing. The information provided by this instrument will be presented in forthcoming articles, once we have accumulated a statistically significant amount of data.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title (up)
Series Volume Series Issue Edition
ISSN 0004-6280 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number IDA @ john @ Serial 195
Permanent link to this record
 

 
Author den Outer, P.; Lolkema, D.; Haaima, M.; van der Hoff, R.; Spoelstra, H.; Schmidt, W.
Title Intercomparisons of nine sky brightness detectors Type Journal Article
Year 2011 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)
Volume 11 Issue 10 Pages 9603-9612
Keywords Calibration; Darkness; *Extraterrestrial Environment; Humans; Light; Luminescent Measurements; Netherlands; *Optical Phenomena; Optics and Photonics/*instrumentation/*methods; Sky Quality Meter; artificial lighting; intercalibration; intercomparison; light pollution; night sky brightness
Abstract Nine Sky Quality Meters (SQMs) have been intercompared during a night time measurement campaign held in the Netherlands in April 2011. Since then the nine SQMs have been distributed across The Netherlands and form the Dutch network for monitoring night sky brightness. The goal of the intercomparison was to infer mutual calibration factors and obtain insight into the variability of the SQMs under different meteorological situations. An ensemble average is built from the individual measurements and used as a reference to infer the mutual calibration factors. Data required additional synchronization prior to the calibration determination, because the effect of moving clouds combined with small misalignments emerges as time jitter in the measurements. Initial scatter of the individual instruments lies between +/-14%. Individual night time sums range from -16% to +20%. Intercalibration reduces this to 0.5%, and -7% to +9%, respectively. During the campaign the smallest luminance measured was 0.657 +/- 0.003 mcd/m(2) on 12 April, and the largest value was 5.94 +/- 0.03 mcd/m(2) on 2 April. During both occurrences interfering circumstances like snow cover or moonlight were absent.
Address National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3720 BA Bilthoven, The Netherlands. peter.den.outer@rivm.nl
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title (up)
Series Volume Series Issue Edition
ISSN 1424-8220 ISBN Medium
Area Expedition Conference
Notes PMID:22163715; PMCID:PMC3231263 Approved no
Call Number IDA @ john @ Serial 196
Permanent link to this record
 

 
Author Baugh, K.; Hsu, F.-C.; Elvidge, C.D.; Zhizhin, M.
Title Nighttime Lights Compositing Using the VIIRS Day-Night Band: Preliminary Results Type Journal Article
Year 2013 Publication Proceedings of the Asia-Pacific Advanced Network Abbreviated Journal APAN Proceedings
Volume 35 Issue Pages 70
Keywords remote sensing; light pollution; VIIRS; satellite; radiometry
Abstract Dramatically improved nighttime lights capabilities are presented by the launch of the National Polar-orbiting Partnership (NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) Day Night Band (DNB) sensor. Building on 18 years of experience compositing nighttime data from the Defense Meteorological Satellite Program (DMSP) Operational Linescan System (OLS), NOAA’s NGDC Earth Observation Group has started adapting their algorithms to process these new data. The concept of compositing nighttime data comprises combining only high quality data components over a period of time to improve sensitivity and coverage. For this work, flag image are compiled to describe image quality. The flag categories include: daytime, twilight, stray light, lunar illuminance, noisy edge of scan data, clouds, and no data. High quality data is defined as not having any of these attributes present. Two methods of reprojection are necessary due to data collection characteristics. Custom algorithms have been created to terrain-correct and reproject all data to a common 15 arc second grid. Results of compositing over two time periods in 2012 are presented to demonstrate data quality and initial capabilities. These data can be downloaded at http://www.ngdc.noaa.gov/eog/viirs/downloadviirsntl.html.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title (up)
Series Volume Series Issue Edition
ISSN 2227-3026 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number IDA @ john @ Serial 197
Permanent link to this record
 

 
Author Elvidge, C.D.; Baugh, K.E.; Zhizhin, M.; Hsu, F.-C.
Title Why VIIRS data are superior to DMSP for mapping nighttime lights Type Journal Article
Year 2013 Publication Proceedings of the Asia-Pacific Advanced Network Abbreviated Journal APAN Proceedings
Volume 35 Issue Pages 62
Keywords
Abstract For more than forty years the U.S. Air Force Defense Meteorological Satellite Program (DMSP) Operational Linescan System (OLS) has been the only satellite system collecting global low-light imaging data. A series of twenty-four DMSP satellites have collected low-light imaging data. The design of the OLS has not changed significantly since satellite F-4 flew in the late 1970’s and OLS data have relatively coarse spatial resolution, limited dynamic range, and lack in-flight calibration. In 2011 NASA and NOAA launched the Suomi National Polar Partnership (SNPP) satellite carrying the first Visible Infrared Imaging Radiometer Suite (VIIRS) instrument. The VIIRS collects low light imaging data and has several improvements over the OLS’ capabilities. In this paper we contrast the nighttime low light imaging collection capabilities of these two systems and compare their data products.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title (up)
Series Volume Series Issue Edition
ISSN 2227-3026 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number IDA @ john @ Serial 198
Permanent link to this record