|
Records |
Links |
|
Author |
Kloog, I.; Stevens, R.G.; Haim, A.; Portnov, B.A. |

|
|
Title |
Nighttime light level co-distributes with breast cancer incidence worldwide |
Type |
Journal Article |
|
Year |
2010 |
Publication |
Cancer Causes & Control : CCC |
Abbreviated Journal |
Cancer Causes Control |
|
|
Volume |
21 |
Issue |
12 |
Pages |
2059-2068 |
|
|
Keywords  |
Adult; Birth Rate; Breast Neoplasms/*epidemiology/etiology; Carcinoma/*epidemiology/etiology; Circadian Rhythm/*physiology; Cohort Studies; Electricity; Female; Humans; Incidence; *Light/adverse effects; Lighting; Photoperiod; Registries; Urban Population/statistics & numerical data; World Health; oncogenesis |
|
|
Abstract |
Breast cancer incidence varies widely among countries of the world for largely unknown reasons. We investigated whether country-level light at night (LAN) is associated with incidence. We compared incidence rates of five common cancers in women (breast, lung, colorectal, larynx, and liver), observed in 164 countries of the world from the GLOBOCAN database, with population-weighted country-level LAN, and with several developmental and environmental indicators, including fertility rate, per capita income, percent of urban population, and electricity consumption. Two types of regression models were used in the analysis: Ordinary Least Squares and Spatial Errors. We found a significant positive association between population LAN level and incidence rates of breast cancer. There was no such an association between LAN level and colorectal, larynx, liver, and lung cancers. A sensitivity test, holding other variables at their average values, yielded a 30-50% higher risk of breast cancer in the highest LAN exposed countries compared to the lowest LAN exposed countries. The possibility that under-reporting from the registries in the low-resource, and also low-LAN, countries created a spurious association was evaluated in several ways and shown not to account for the results. These findings provide coherence of the previously reported case-control and cohort studies with the co-distribution of LAN and breast cancer in entire populations. |
|
|
Address |
Department of Natural Resources & Environmental Management, University of Haifa, 31905 Mount Carmel, Haifa, Israel |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0957-5243 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:20680434 |
Approved |
no |
|
|
Call Number |
IDA @ john @ |
Serial |
160 |
|
Permanent link to this record |
|
|
|
|
Author |
Peplonska, B.; Bukowska, A.; Sobala, W.; Reszka, E.; Gromadzinska, J.; Wasowicz, W.; Lie, J.A.; Kjuus, H.; Ursin, G. |

|
|
Title |
Rotating night shift work and mammographic density |
Type |
Journal Article |
|
Year |
2012 |
Publication |
Cancer Epidemiology, Biomarkers & Prevention : a Publication of the American Association for Cancer Research, Cosponsored by the American Society of Preventive Oncology |
Abbreviated Journal |
Cancer Epidemiol Biomarkers Prev |
|
|
Volume |
21 |
Issue |
7 |
Pages |
1028-1037 |
|
|
Keywords  |
Adult; Breast/*pathology; Breast Neoplasms/*etiology/*pathology; Circadian Rhythm/*physiology; Cross-Sectional Studies; Female; Humans; Melatonin/urine; Middle Aged; *Midwifery; *Nursing Staff; Questionnaires; Risk Factors; *Work Schedule Tolerance; oncogenesis |
|
|
Abstract |
BACKGROUND: An increased risk of breast cancer has been observed in night shift workers. Exposure to artificial light at night and disruption of the endogenous circadian rhythm with suppression of the melatonin synthesis have been suggested mechanisms. We investigated the hypothesis that rotating night shift work is associated with mammographic density. METHODS: We conducted a cross-sectional study on the association between rotating night shift work characteristics, 6-sulfatoxymelatonin (MT6s) creatinine adjusted in a spot morning urine sample, and a computer-assisted measure of mammographic density in 640 nurses and midwives ages 40 to 60 years. The associations were evaluated using regression models adjusted for age, body mass index, menopausal status, age at menopause, age at menarche, smoking, and the calendar season of the year when mammography was conducted. RESULTS: The adjusted means of percentage of mammographic density and absolute density were slightly higher among women working rotating night shifts but not statistically significant [percentage of mammographic density = 23.6%, 95% confidence interval (CI), 21.9%-25.4% vs. 22.5%, 95% CI, 20.8%-24.3%; absolute density = 23.9 cm(2), 95% CI, 21.4-26.4 cm(2) vs. 21.8 cm(2), 95% CI, 19.4-24.3 cm(2) in rotating night shift and day shift nurses, respectively). There were no significant associations between the current or cumulative rotating night shift work exposure metrics and mammographic density. No association was observed between morning MT6s and mammographic density. CONCLUSIONS: The hypothesis on the link between rotating night shift work, melatonin synthesis disruption, and mammographic density is not supported by the results of the present study. IMPACT: It is unlikely that the development of breast cancer in nurses working rotating night shifts is mediated by an increase in mammographic density. |
|
|
Address |
Department of Environmental Epidemiology, Nofer Institute of Occupational Medicine, Lodz, Poland. beatap@imp.lodz.pl |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1055-9965 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:22539602 |
Approved |
no |
|
|
Call Number |
IDA @ john @ |
Serial |
159 |
|
Permanent link to this record |
|
|
|
|
Author |
Cajochen, C.; Frey, S.; Anders, D.; Spati, J.; Bues, M.; Pross, A.; Mager, R.; Wirz-Justice, A.; Stefani, O. |

|
|
Title |
Evening exposure to a light-emitting diodes (LED)-backlit computer screen affects circadian physiology and cognitive performance |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Journal of Applied Physiology (Bethesda, Md. : 1985) |
Abbreviated Journal |
J Appl Physiol (1985) |
|
|
Volume |
110 |
Issue |
5 |
Pages |
1432-1438 |
|
|
Keywords  |
Adult; Circadian Rhythm/*physiology/radiation effects; Cognition/*physiology/radiation effects; *Computer Terminals; Humans; Light; Lighting/*methods; Male; Photic Stimulation/*methods; Radiation Dosage; Semiconductors; *Task Performance and Analysis; Young Adult; blue light; sleep; circadian disruption |
|
|
Abstract |
Many people spend an increasing amount of time in front of computer screens equipped with light-emitting diodes (LED) with a short wavelength (blue range). Thus we investigated the repercussions on melatonin (a marker of the circadian clock), alertness, and cognitive performance levels in 13 young male volunteers under controlled laboratory conditions in a balanced crossover design. A 5-h evening exposure to a white LED-backlit screen with more than twice as much 464 nm light emission {irradiance of 0,241 Watt/(steradian x m(2)) [W/(sr x m(2))], 2.1 x 10(13) photons/(cm(2) x s), in the wavelength range of 454 and 474 nm} than a white non-LED-backlit screen [irradiance of 0,099 W/(sr x m(2)), 0.7 x 10(13) photons/(cm(2) x s), in the wavelength range of 454 and 474 nm] elicited a significant suppression of the evening rise in endogenous melatonin and subjective as well as objective sleepiness, as indexed by a reduced incidence of slow eye movements and EEG low-frequency activity (1-7 Hz) in frontal brain regions. Concomitantly, sustained attention, as determined by the GO/NOGO task; working memory/attention, as assessed by “explicit timing”; and declarative memory performance in a word-learning paradigm were significantly enhanced in the LED-backlit screen compared with the non-LED condition. Screen quality and visual comfort were rated the same in both screen conditions, whereas the non-LED screen tended to be considered brighter. Our data indicate that the spectral profile of light emitted by computer screens impacts on circadian physiology, alertness, and cognitive performance levels. The challenge will be to design a computer screen with a spectral profile that can be individually programmed to add timed, essential light information to the circadian system in humans. |
|
|
Address |
Centre for Chronobiology, Psychiatric Hospitals of the University of Basel, Basel, Switzerland. christian.cajochen@upkbs.ch |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0161-7567 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:21415172 |
Approved |
no |
|
|
Call Number |
IDA @ john @ |
Serial |
293 |
|
Permanent link to this record |
|
|
|
|
Author |
Mottram, V.; Middleton, B.; Williams, P.; Arendt, J. |

|
|
Title |
The impact of bright artificial white and 'blue-enriched' light on sleep and circadian phase during the polar winter |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Journal of Sleep Research |
Abbreviated Journal |
J Sleep Res |
|
|
Volume |
20 |
Issue |
1 Pt 2 |
Pages |
154-161 |
|
|
Keywords  |
Adult; Circadian Rhythm/*physiology; *Cold Climate; Female; Humans; *Light; Male; Medical Records; Questionnaires; Sleep/*physiology; Time Factors; blue light |
|
|
Abstract |
Delayed sleep phase (and sometimes free-run) is common in the Antarctic winter (no natural sunlight) and optimizing the artificial light conditions is desirable. This project evaluated sleep when using 17,000 K blue-enriched lamps compared with standard white lamps (5000 K) for personal and communal illumination. Base personnel, 10 males, five females, 32.5+/-8 years took part in the study. From 24 March to 21 September 2006 light exposure alternated between 4-5-week periods of standard white (5000 K) and blue-enriched lamps (17,000 K), with a 3-week control before and after extra light. Sleep and light exposure were assessed by actigraphy and sleep diaries. General health (RAND 36-item questionnaire) and circadian phase (urinary 6-sulphatoxymelatonin rhythm) were evaluated at the end of each light condition. Direct comparison (rmanova) of blue-enriched light with white light showed that sleep onset was earlier by 19 min (P=0.022), and sleep latency tended to be shorter by 4 min (P=0.065) with blue-enriched light. Analysing all light conditions, control, blue and white, again provided evidence for greater efficiency of blue-enriched light compared with white (P<0.05), but with the best sleep timing, duration, efficiency and quality in control natural light conditions. Circadian phase was earlier on average in midwinter blue compared with midwinter white light by 45 min (P<0.05). Light condition had no influence on general health. We conclude that the use of blue-enriched light had some beneficial effects, notably earlier sleep, compared with standard white light during the polar winter. |
|
|
Address |
British Antarctic Survey Medical Unit, Derriford Hospital, Plymouth, UK |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0962-1105 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:20723022 |
Approved |
no |
|
|
Call Number |
IDA @ john @ |
Serial |
348 |
|
Permanent link to this record |
|
|
|
|
Author |
Smith, M.R.; Revell, V.L.; Eastman, C.I. |

|
|
Title |
Phase advancing the human circadian clock with blue-enriched polychromatic light |
Type |
Journal Article |
|
Year |
2009 |
Publication |
Sleep Medicine |
Abbreviated Journal |
Sleep Med |
|
|
Volume |
10 |
Issue |
3 |
Pages |
287-294 |
|
|
Keywords  |
Adult; Circadian Rhythm/*radiation effects; Female; Humans; *Light; Lighting/*methods; Male; Melatonin/metabolism; Phototherapy/*methods; Sleep; Wakefulness; Young Adult; blue light; sleep |
|
|
Abstract |
BACKGROUND: Previous studies have shown that the human circadian system is maximally sensitive to short-wavelength (blue) light. Whether this sensitivity can be utilized to increase the size of phase shifts using light boxes and protocols designed for practical settings is not known. We assessed whether bright polychromatic lamps enriched in the short-wavelength portion of the visible light spectrum could produce larger phase advances than standard bright white lamps. METHODS: Twenty-two healthy young adults received either a bright white or bright blue-enriched 2-h phase advancing light pulse upon awakening on each of four treatment days. On the first treatment day the light pulse began 8h after the dim light melatonin onset (DLMO), on average about 2h before baseline wake time. On each subsequent day, light treatment began 1h earlier than the previous day, and the sleep schedule was also advanced. RESULTS: Phase advances of the DLMO for the blue-enriched (92+/-78 min, n=12) and white groups (76+/-45 min, n=10) were not significantly different. CONCLUSION: Bright blue-enriched polychromatic light is no more effective than standard bright light therapy for phase advancing circadian rhythms at commonly used therapeutic light levels. |
|
|
Address |
Biological Rhythms Research Laboratory, Rush University Medical Center, Suite 425, 1645 W. Jackson Boulevard, Chicago, IL 60612, USA |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1389-9457 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:18805055; PMCID:PMC2723863 |
Approved |
no |
|
|
Call Number |
IDA @ john @ |
Serial |
289 |
|
Permanent link to this record |