|   | 
Details
   web
Records
Author Kocifaj, M.
Title Light-pollution model for cloudy and cloudless night skies with ground-based light sources Type Journal Article
Year 2007 Publication Applied Optics Abbreviated Journal Appl. Opt.
Volume 46 Issue 15 Pages 3013
Keywords light pollution; modeling
Abstract The scalable theoretical model of light pollution for ground sources is presented. The model is successfully employed for simulation of angular behavior of the spectral and integral sky radiance and∕or luminance during nighttime. There is no restriction on the number of ground-based light sources or on the spatial distribution of these sources in the vicinity of the measuring point (i.e., both distances and azimuth angles of the light sources are configurable). The model is applicable for real finite-dimensional surface sources with defined spectral and angular radiating properties contrary to frequently used point-source approximations. The influence of the atmosphere on the transmitted radiation is formulated in terms of aerosol and molecular optical properties. Altitude and spectral reflectance of a cloud layer are the main factors introduced for simulation of cloudy and∕or overcast conditions. The derived equations are translated into numerically fast code, and it is possible to repeat the entire set of calculations in real time. The parametric character of the model enables its efficient usage by illuminating engineers and∕or astronomers in the study of various light-pollution situations. Some examples of numerical runs in the form of graphical results are presented.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume (down) Series Issue Edition
ISSN 0003-6935 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number IDA @ john @ Serial 277
Permanent link to this record
 

 
Author Xavier Kerola, D.
Title Modelling artificial night-sky brightness with a polarized multiple scattering radiative transfer computer code: Modelling artificial night-sky brightness Type Journal Article
Year 2006 Publication Monthly Notices of the Royal Astronomical Society Abbreviated Journal
Volume 365 Issue 4 Pages 1295-1299
Keywords Skyglow; modeling; radiative transfer; Gauss-Seidel; light pollution; Garstang model
Abstract As part of an ongoing investigation of radiative effects produced by hazy atmospheres, computational procedures have been developed for use in determining the brightening of the night sky as a result of urban illumination. The downwardly and upwardly directed radiances of multiply scattered light from an offending metropolitan source are computed by a straightforward Gauss-Seidel (G-S) iterative technique applied directly to the integrated form of Chandrasekhar's vectorized radiative transfer equation. Initial benchmark night-sky brightness tests of the present G-S model using fully consistent optical emission and extinction input parameters yield very encouraging results when compared with the double scattering treatment of Garstang, the only full-fledged previously available model.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume (down) Series Issue Edition
ISSN 0035-8711 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number IDA @ john @ Serial 278
Permanent link to this record
 

 
Author Johansson, M.; Pedersen, E.; Maleetipwan-Mattsson, P.; Kuhn, L.; Laike, T.
Title Perceived outdoor lighting quality (POLQ): A lighting assessment tool Type Journal Article
Year 2013 Publication Journal of Environmental Psychology Abbreviated Journal Journal of Environmental Psychology
Volume 39 Issue Pages 14-21
Keywords Perception; Street lighting; Observation-based environmental assessment; Urban space
Abstract A shift towards more energy-efficient light sources for outdoor lighting such as light-emitting diodes (LEDs) is underway. Photometric measures are not sufficient to capture how users experience the light, so complementary tools are required. This study aimed to develop an observer-based environmental assessment tool, based on bipolar semantic differentials, for outdoor lighting in urban spaces. Exploratory (N = 130) and confirmatory (N = 117) factor analyses of observations of lighting installations made by laypersons on-site along pedestrian paths, resulted in two dimensions of high reliability: the Perceived Strength Quality (PSQ, Cronbach's alpha = 0.82–0.85) and the Perceived Comfort Quality (PCQ, Cronbach's alpha = 0.77–0.81). PSQ and PCQ differentiated between light sources of different illuminance level, colour temperature and colour rendering. Regression analyses showed that the perceived lighting qualities helped to explain the variance in visual accessibility, whereas PCQ helped to explain perceived danger in the environment. The perceived lighting qualities can add to the understanding of pedestrians' perception of outdoor lighting, and is proposed as a complementary tool for development of sustainable light designs in the urban environment.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume (down) Series Issue Edition
ISSN 0272-4944 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number IDA @ john @ Serial 279
Permanent link to this record
 

 
Author Kuhn, L.; Johansson, M.; Laike, T.; Goven, T.
Title Residents' perceptions following retrofitting of residential area outdoor lighting with LEDs Type Journal Article
Year 2013 Publication Lighting Research and Technology Abbreviated Journal Lighting Research and Technology
Volume 45 Issue 5 Pages 568-584
Keywords *Lighting; outdoor lighting; LED; light emitting diode; lighting levels; public opinion
Abstract The use of light emitting diodes (LEDs) in outdoor lighting has energy-saving potential, but users’ responses to this light source are largely unknown. An intervention study in two residential areas compared conventional lighting installations (high pressure sodium in Area 1 and high pressure mercury in Area 2) to a retrofitted LED-alternative regarding residents’ perceptions of quality of light, visual accessibility and danger. Moreover, energy use was calculated. Residents’ (N = 60) visual accessibility improved and perceived danger remained low in both areas after retrofitting. In Area 2 the perceived quality of light increased, whereas in Area 1 the results were mixed. The retrofitted application reduced energy use by 41–76% and might be a feasible alternative to conventional outdoor lighting in relatively safe areas.
Address Environmental Psychology, Department of Architecture and Built Environment, Lund University, Lund, Sweden
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume (down) Series Issue Edition
ISSN 1477-1535 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number IDA @ john @ Serial 280
Permanent link to this record
 

 
Author Zukauskas, A.; Vaicekauskas, R.; Tuzikas, A.; Petrulis, A.; Stanikunas, R.; Svegzda, A.; Eidikas, P.; Vitta, P.
Title Firelight LED Source: Toward a Balanced Approach to the Performance of Solid-State Lighting for Outdoor Environments Type Journal Article
Year 2014 Publication IEEE Photonics Journal Abbreviated Journal IEEE Photonics J.
Volume 6 Issue 3 Pages 1-16
Keywords LED; lighting; lighting technology; light emitting diode; firelight LED
Abstract We report on a blue-amber (“firelight”) cluster of light-emitting diodes (LEDs) with extra-low correlated color temperature (~1860 K) optimized for outdoor lighting under mesopic conditions. When compared with common white LEDs, the firelight LED cluster shows considerably reduced indexes of melatonin suppression and skyglow, increased retinal illuminance for elderly people, but a reduced performance of perceiving colors, which, however, can be tolerated at mesopic luminance. In comparison with an almost metameric high-pressure sodium lamp, the cluster exhibits a potentially higher luminous efficacy, similar reaction time and detection threshold of luminance contrasts for achromatic targets, and noticeably improved color discrimination characteristics.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume (down) Series Issue Edition
ISSN 1943-0655 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number IDA @ john @ Serial 281
Permanent link to this record