toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Kyba, C.C.M.; Hölker, F. url  doi
openurl 
  Title Do artificially illuminated skies affect biodiversity in nocturnal landscapes? Type Journal Article
  Year 2013 Publication Landscape Ecology Abbreviated Journal (up) Landscape Ecol  
  Volume 28 Issue 9 Pages 1637-1640  
  Keywords skyglow; light pollution; biodiversity  
  Abstract The skyglow from cities at night is one of the most dramatic modifications that humans have made to Earth’s biosphere, and it is increasingly extending into nocturnal landscapes (nightscapes) far beyond urban areas. This scattered light is dim and homogenous compared to a lit street, but can be bright compared to natural celestial light sources, such as stars. Because of the large area of Earth affected by artificial skyglow, it is essential to verify whether skyglow is a selective pressure in nocturnal landscapes. We propose two scientific approaches that could examine whether skyglow affects biodiversity.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0921-2973 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 35  
Permanent link to this record
 

 
Author Kuhn, L.; Johansson, M.; Laike, T.; Goven, T. url  doi
openurl 
  Title Residents' perceptions following retrofitting of residential area outdoor lighting with LEDs Type Journal Article
  Year 2013 Publication Lighting Research and Technology Abbreviated Journal (up) Lighting Research and Technology  
  Volume 45 Issue 5 Pages 568-584  
  Keywords *Lighting; outdoor lighting; LED; light emitting diode; lighting levels; public opinion  
  Abstract The use of light emitting diodes (LEDs) in outdoor lighting has energy-saving potential, but users’ responses to this light source are largely unknown. An intervention study in two residential areas compared conventional lighting installations (high pressure sodium in Area 1 and high pressure mercury in Area 2) to a retrofitted LED-alternative regarding residents’ perceptions of quality of light, visual accessibility and danger. Moreover, energy use was calculated. Residents’ (N = 60) visual accessibility improved and perceived danger remained low in both areas after retrofitting. In Area 2 the perceived quality of light increased, whereas in Area 1 the results were mixed. The retrofitted application reduced energy use by 41–76% and might be a feasible alternative to conventional outdoor lighting in relatively safe areas.  
  Address Environmental Psychology, Department of Architecture and Built Environment, Lund University, Lund, Sweden  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1477-1535 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 280  
Permanent link to this record
 

 
Author Gil-de-Castro, A.; Moreno-Munoz, A.; Larsson, A.; de la Rosa, J.; Bollen, M. url  doi
openurl 
  Title LED street lighting: A power quality comparison among street light technologies Type Journal Article
  Year 2013 Publication Lighting Research and Technology Abbreviated Journal (up) Lighting Research and Technology  
  Volume 45 Issue 6 Pages 710-728  
  Keywords LED; LED lighting; high-pressure sodium; HPS; outdoor lighting; lighting technology  
  Abstract High-pressure sodium lamps are currently the main lamps used in public lighting. However, the possibility of using high-power light emitting diode (LEDs) for street lighting is growing continuously due to their greater energy efficiency, robustness, long life and light control. The aim of this paper is to study the power quality of high-power lighting networks based on LED and high-pressure sodium lamps. Both electromagnetic and dimmable electronic ballasts, which can dim the lamp output smoothly and uniformly, have been used connected to high-pressure sodium lamps. High-pressure sodium lamps connected to electronic equipment have been tested with different arc power levels using dimming on a 230 V power supply. The study presented in this paper is completely based on measurements, including harmonic currents in the frequency range up to 150 kHz for all the technologies. The main results show a broadband spectrum in LED lamps which confirms other research in fluorescent lamps powered by high-frequency ballasts. Results also indicate a decrease in the harmonic value with increasing harmonic order, and a decrease in the harmonic value at half load (60%) compared with full load (100%). Although total harmonic distortion of the current is lower with high-pressure sodium lamps connected to electronic rather than electromagnetic ballasts, LED lamps achieved the lowest total harmonic distortion of current.  
  Address Department of Computer Architecture, Electronics and Electronic Technology, University of Cordoba, Cordoba, Spain  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1477-1535 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 333  
Permanent link to this record
 

 
Author Sweater-Hickcox, K.; Narendran, N.; Bullough, J.; Freyssinier, J. url  doi
openurl 
  Title Effect of different coloured luminous surrounds on LED discomfort glare perception Type Journal Article
  Year 2013 Publication Lighting Research and Technology Abbreviated Journal (up) Lighting Research and Technology  
  Volume 45 Issue 4 Pages 464-475  
  Keywords perception; subjective; LED; LED lighting; spectral power distribution; SPD  
  Abstract Recently, there has been increased interest in energy-efficient lighting as energy resources become higher in demand. Anecdotal evidence suggests that certain populations believe light-emitting diodes (LED) produce more glare than traditional technologies. This may be due to a number of factors such as spectral power distribution (SPD), source luminance, or beam intensity distribution. A study was conducted to assess the effect of different SPDs on the perception of discomfort glare from an LED source. For the range of conditions evaluated, the presence of any luminous surround significantly reduced the perception of discomfort glare from the LED array. The blue luminous surround reduced discomfort glare perception significantly less than the white or the yellow luminous surrounds. The implications for solid-state lighting systems are discussed.  
  Address Lighting Research Center, Rensselaer Polytechnic Institute, Troy, NY, USA  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1477-1535 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 338  
Permanent link to this record
 

 
Author Kostic, A.; Kremic, M.; Djokic, L.; Kostic, M. url  doi
openurl 
  Title Light-emitting diodes in street and roadway lighting – a case study involving mesopic effects Type Journal Article
  Year 2013 Publication Lighting Research and Technology Abbreviated Journal (up) Lighting Research and Technology  
  Volume 45 Issue 2 Pages 217-229  
  Keywords LED; LED lighting; mesopic; street lighting; outdoor lighting; roadway lighting  
  Abstract The paper considers the justification for the application of light-emitting diode (LED) technology to urban lighting. The results suggest that LEDs are convenient for architectural lighting and deserve to be considered for use in ambient lighting. The recently developed Commission Internationale de l’Eclairage (CIE) mesopic system enabled the inclusion of mesopic effects into a comprehensive techno-economic analysis, which dealt with efficiency, maintenance and financial aspects of the use of LEDs in street and roadway lighting. It is concluded that the average energy savings when using LED instead of high-pressure sodium (HPS) luminaires amount to 19–26% for single-sided, staggered and opposite layouts, although they are frequently negligible if mesopic effects are not included. The total costs of the LED lighting solutions, even including mesopic effects, are 1.36 to 6.44 times higher than those of the comparable HPS lighting solutions. Therefore, LEDs are questionable for street and roadway lighting.  
  Address Faculty of Architecture, University of Belgrade, Belgrade, Serbia  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1477-1535 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 339  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: