toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Fonken, L.K.; Weil, Z.M.; Nelson, R.J. url  doi
openurl 
  Title Dark nights reverse metabolic disruption caused by dim light at night Type Journal Article
  Year 2013 Publication Obesity (Silver Spring, Md.) Abbreviated Journal Obesity (Silver Spring)  
  Volume 21 Issue 6 Pages 1159-1164  
  Keywords Animals; Body Mass Index; Energy Intake; Gene Expression; Glucose Tolerance Test; *Light; Male; Mice; Obesity/*epidemiology/etiology; *Photoperiod; Weight Gain  
  Abstract OBJECTIVE: The increasing prevalence of obesity and related metabolic disorders coincides with increasing exposure to light at night. Previous studies report that mice exposed to dim light at night (dLAN) develop symptoms of metabolic syndrome. This study investigated whether mice returned to dark nights after dLAN exposure recover metabolic function. DESIGN AND METHODS: Male Swiss-Webster mice were assigned to either: standard light-dark (LD) conditions for 8 weeks (LD/LD), dLAN for 8 weeks (dLAN/dLAN), LD for 4 weeks followed by 4 weeks of dLAN (LD/dLAN), and dLAN for 4 weeks followed by 4 weeks of LD (dLAN/LD). RESULTS: After 4 weeks in their respective lighting conditions both groups initially placed in dLAN increased body mass gain compared to LD mice. Half of the dLAN mice (dLAN/LD) were then transferred to LD and vice versa (LD/dLAN). Following the transfer dLAN/dLAN and LD/dLAN mice gained more weight than LD/LD and dLAN/LD mice. At the conclusion of the study dLAN/LD mice did not differ from LD/LD mice with respect to weight gain and had lower fat pad mass compared to dLAN/dLAN mice. Compared to all other groups dLAN/dLAN mice decreased glucose tolerance as indicated by an intraperitoneal glucose tolerance test at week 7, indicating that dLAN/LD mice recovered glucose metabolism. dLAN/dLAN mice also increased MAC1 mRNA expression in peripheral fat as compared to both LD/LD and dLAN/LD mice, suggesting peripheral inflammation is induced by dLAN, but not sustained after return to LD. CONCLUSION: These results suggest that re-exposure to dark nights ameliorates metabolic disruption caused by dLAN exposure.  
  Address Department of Neuroscience and Institute for Behavioral Medicine Research, Wexner Medical Center, Ohio State University, Columbus, Ohio 43210, USA. fonken.1@osu.edu  
  Corporate Author Thesis  
  Publisher (down) Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1930-7381 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:23666854 Approved no  
  Call Number IDA @ john @ Serial 167  
Permanent link to this record
 

 
Author Obayashi, K.; Saeki, K.; Iwamoto, J.; Okamoto, N.; Tomioka, K.; Nezu, S.; Ikada, Y.; Kurumatani, N. url  doi
openurl 
  Title Exposure to light at night, nocturnal urinary melatonin excretion, and obesity/dyslipidemia in the elderly: a cross-sectional analysis of the HEIJO-KYO study Type Journal Article
  Year 2013 Publication The Journal of Clinical Endocrinology and Metabolism Abbreviated Journal J Clin Endocrinol Metab  
  Volume 98 Issue 1 Pages 337-344  
  Keywords *Aged; Aged, 80 and over; Case-Control Studies; *Circadian Rhythm/physiology; Cross-Sectional Studies; Dyslipidemias/complications/metabolism/*urine; Female; Humans; Japan; *Light; Male; Melatonin/secretion/*urine; Obesity/complications/metabolism/*urine; Photoperiod  
  Abstract CONTEXT: Obesity and exposure to light at night (LAN) have increased globally. Although LAN suppresses melatonin secretion and disturbs body mass regulation in experimental settings, its associations with melatonin secretion, obesity, and other metabolic consequences in uncontrolled home settings remain unclear. OBJECTIVE: The aim of this study was to determine the association of exposure to LAN in an uncontrolled home setting with melatonin secretion, obesity, dyslipidemia, and diabetes. DESIGN AND PARTICIPANTS: A cross-sectional study was performed in 528 elderly individuals (mean age, 72.8 yr). MEASURES: The intensity of LAN in the bedroom was measured at 1-min intervals during two consecutive nights, along with overnight urinary melatonin excretion and metabolic parameters. RESULTS: Compared with the Dim group (average <3 lux; n = 383), the LAN group (average >/=3 lux; n = 145) showed significantly higher body weight (adjusted mean, 58.8 vs. 56.6 kg; P = 0.01), body mass index (23.3 vs. 22.7 kg/m(2); P = 0.04), waist circumference (84.9 vs. 82.8 cm; P = 0.01), triglyceride levels (119.7 vs. 99.5 mg/dl; P < 0.01), and low-density lipoprotein cholesterol levels (128.6 vs. 122.2 mg/dl; P = 0.04), and showed significantly lower high-density lipoprotein cholesterol levels (57.4 vs. 61.3 mg/dl; P = 0.02). These associations were independent of numerous potential confounders, including urinary melatonin excretion. Furthermore, LAN exposure is associated with higher odds ratios (ORs) for obesity (body mass index: OR, 1.89; P = 0.02; abdominal: OR, 1.62; P = 0.04) and dyslipidemia (OR, 1.72; P = 0.02) independent of demographic and socioeconomic parameters. In contrast, urinary melatonin excretion and glucose parameters did not show significant differences between the two groups. CONCLUSIONS: Exposure to LAN in an uncontrolled home setting is associated with impaired obese and lipid parameters independent of nocturnal urinary melatonin excretion in elderly individuals. Moreover, LAN exposure is associated with higher ORs for obesity and dyslipidemia independent of demographic and socioeconomic parameters.  
  Address Department of Community Health and Epidemiology, Nara Medical University School of Medicine, 840 Shijocho, Kashiharashi, Nara, 634-8521, Japan. obayashi@naramed-u.ac.jp  
  Corporate Author Thesis  
  Publisher (down) Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0021-972X ISBN Medium  
  Area Expedition Conference  
  Notes PMID:23118419 Approved no  
  Call Number IDA @ john @ Serial 168  
Permanent link to this record
 

 
Author Nievas Rosillo, M. pdf  url
openurl 
  Title Absolute photometry and Night Sky Brightness with all-sky cameras Type Report
  Year 2013 Publication e-prints Complutense Abbreviated Journal e-prints Complutense  
  Volume Issue 24626 Pages  
  Keywords Instrumentation; skyglow; measurement; modeling  
  Abstract All-sky cameras have proven to be powerful tools to continuously monitoring the sky in a wide range of fields in both Astrophysics and Meteorology. In this work, we have developed a complete software pipeline to analyze the night CCD images obtained with one of such systems. This let us to study typical parameters used in Astrophysics to characterize the night sky quality, such as the Sky Brightness, the Cloud Coverage and the Atmospheric Extinction, how they evolve over the time and their variability. Using our software, we analyzed a large set of data from AstMon-OT all-sky camera at Teide Observatory. Results from this work have been applied in the support to the spanish CTA site proposal at Izaña, Tenerife and are being discussed within the CTA consortium. A comparison with data from other devices that have been used in site characterization such as the IAC80 telescope is also presented. This comparison is used to validate the results of the analysis of all-sky images. Finally, we test our software with AstMon-UCM and DSLR cameras. Some general recommendations for the use of DSLR cameras are provided.  
  Address Departamento de Astrofí­sica y Ciencias de la Atmosfera, Universidad Complutense de Madrid, Madrid, Spain  
  Corporate Author Thesis Master's thesis  
  Publisher (down) Place of Publication Madrid Editor  
  Language English Summary Language English Original Title  
  Series Editor Series Title e-prints Complutense Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 1437  
Permanent link to this record
 

 
Author Femia, N.; Fortunato, M.; Vitelli, M. url  doi
openurl 
  Title Light-to-Light: PV-Fed LED Lighting Systems Type Journal Article
  Year 2013 Publication IEEE Transactions on Power Electronics Abbreviated Journal IEEE Trans. Power Electron.  
  Volume 28 Issue 8 Pages 4063-4073  
  Keywords light-to-light systems; outdoor lighting; lighting technology; LED; LED lighting; photovoltaics; PV  
  Abstract This paper discusses the principle of operation, dynamic modeling, and control design for light-to-light (LtL) systems, whose aim is to directly convert the sun irradiation into artificial light. The system discussed in this paper is composed by a photovoltaic (PV) panel, an LED array, a dc-dc converter dedicated to the maximum power point tracking of the PV panel and a dc-dc converter dedicated to drive the LEDs array. A system controller is also included, whose goal is to ensure the matching between the maximum available PV power and the LED power by means of a low-frequency LEDs dimming. An experimental design example is discussed to illustrate the functionalities of the LtL system.  
  Address Dipt. di Ing. Elettron. e Ing. Inf., Univ. of Salerno, Salerno, Italy  
  Corporate Author Thesis  
  Publisher (down) Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0885-8993 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 331  
Permanent link to this record
 

 
Author Schnitt, S.; Ruhtz, T.; Fischer, J.; Hölker, F.; Kyba, C.C.M. url  doi
openurl 
  Title Temperature stability of the sky quality meter Type Journal Article
  Year 2013 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)  
  Volume 13 Issue 9 Pages 12166-12174  
  Keywords *Artifacts; Atmosphere/*analysis; Environmental Monitoring/*instrumentation; Equipment Design; Equipment Failure Analysis; Photometry/*instrumentation; Reproducibility of Results; Sensitivity and Specificity; Temperature; *Transducers; Sky Quality Meter; SQM  
  Abstract The stability of radiance measurements taken by the Sky Quality Meter (SQM)was tested under rapidly changing temperature conditions during exposure to a stable light field in the laboratory. The reported radiance was found to be negatively correlated with temperature, but remained within 7% of the initial reported radiance over a temperature range of -15 degrees C to 35 degrees C, and during temperature changes of -33 degrees C/h and +70 degrees C/h.This is smaller than the manufacturer's quoted unit-to-unit systematic uncertainty of 10%,indicating that the temperature compensation of the SQM is adequate under expected outdoor operating conditions.  
  Address Institute for Space Sciences, Freie Universitat Berlin, Carl-Heinrich-Becker-Weg 6-10, Berlin 12165, Germany. christopher.kyba@wew.fu-berlin.de  
  Corporate Author Thesis  
  Publisher (down) Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:24030682; PMCID:PMC3821345 Approved no  
  Call Number IDA @ john @ Serial 194  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: