toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Zheng, Q.; Weng, Q.; Huang, L.; Wang, K.; Deng, J.; Jiang, R.; Ye, Z.; Gan, M. url  doi
openurl 
  Title A new source of multi-spectral high spatial resolution night-time light imagery—JL1-3B Type Journal Article
  Year 2018 Publication Remote Sensing of Environment Abbreviated Journal Remote Sensing of Environment  
  Volume 215 Issue Pages (down) 300-312  
  Keywords Remote Sensing  
  Abstract Artificial light at night (ALAN) provides a unique footprint of human activities and settlements. However, the adverse effects of ALAN on human health and ecosystems have not been well understood. Because of a lack of high resolution data, studies of ALAN in China have been confined to coarse resolution, and fine-scale details are missing. The fine details of ALAN are pertinent, because the highly dense population in Chinese cities has created a distinctive urban lighting pattern. In this paper, we introduced a new generation of high spatial resolution and multi-spectral night-time light imagery from the satellite JL1-3B. We examined its effectiveness for monitoring the spatial pattern and discriminating the types of artificial light based on a case study of Hangzhou, China. Specifically, local Moran's I analysis was applied to identify artificial light hotspots. Then, we analyzed the relationship between artificial light brightness and land uses at the parcel-level, which were generated from GF-2 imagery and open social datasets. Third, a machine learning based method was proposed to discriminate the type of lighting sources – between high pressure sodium lamps (HPS) and light-emitting diode lamps (LED) – by incorporating their spectral information and morphology feature. The result shows a complicated heterogeneity of illumination characteristics across different land uses, where main roads, commercial and institutional areas were brightly lit while residential area, industrial area and agricultural land were dark at night. It further shows that the proposed method was effective at separating light emitted by HPS and LED, with an overall accuracy and kappa coefficient of 83.86% and 0.67, respectively. This study demonstrates the effectiveness of JL1-3B and its superiority over previous night-time light data in detecting details of lighting objects and the nightscape pattern, and suggests that JL1-3B and alike could open up new opportunities for the advancement of night-time remote sensing.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0034-4257 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 1945  
Permanent link to this record
 

 
Author Griepentrog, J.E.; Labiner, H.E.; Gunn, S.R.; Rosengart, M.R. url  doi
openurl 
  Title Bright environmental light improves the sleepiness of nightshift ICU nurses Type Journal Article
  Year 2018 Publication Critical Care (London, England) Abbreviated Journal Crit Care  
  Volume 22 Issue 1 Pages (down) 295  
  Keywords Circadian; Light; Night shift; Nurse; Shift work sleep disorder  
  Abstract BACKGROUND: Shift work can disturb circadian homeostasis and result in fatigue, excessive sleepiness, and reduced quality of life. Light therapy has been shown to impart positive effects in night shift workers. We sought to determine whether or not prolonged exposure to bright light during a night shift reduces sleepiness and enhances psychomotor performance among ICU nurses.

METHODS: This is a single-center randomized, crossover clinical trial at a surgical trauma ICU. ICU nurses working a night shift were exposed to a 10-h period of high illuminance (1500-2000 lx) white light compared to standard ambient fluorescent lighting of the hospital. They then completed the Stanford Sleepiness Scale and the Psychomotor Vigilance Test. The primary and secondary endpoints were analyzed using the paired t test. A p value <0.05 was considered significant.

RESULTS: A total of 43 matched pairs completed both lighting exposures and were analyzed. When exposed to high illuminance lighting subjects experienced reduced sleepiness scores on the Stanford Sleepiness Scale than when exposed to standard hospital lighting: mean (sem) 2.6 (0.2) vs. 3.0 (0.2), p = 0.03. However, they committed more psychomotor errors: 2.3 (0.2) vs. 1.7 (0.2), p = 0.03.

CONCLUSIONS: A bright lighting environment for ICU nurses working the night shift reduces sleepiness but increases the number of psychomotor errors.

TRIAL REGISTRATION: ClinicalTrials.gov, NCT03331822 . Retrospectively registered on 6 November 2017.
 
  Address Department of Critical Care Medicine, University of Pittsburgh, Pittsburgh, PA, USA. rosengartmr@upmc.edu  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1364-8535 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:30424793 Approved no  
  Call Number GFZ @ kyba @ Serial 2070  
Permanent link to this record
 

 
Author Wood, J.M.; Isoardi, G.; Black, A.; Cowling, I. url  doi
openurl 
  Title Night-time driving visibility associated with LED streetlight dimming Type Journal Article
  Year 2018 Publication Accident; Analysis and Prevention Abbreviated Journal Accid Anal Prev  
  Volume 121 Issue Pages (down) 295-300  
  Keywords Public Safety  
  Abstract New LED streetlighting designs and dimming are being introduced worldwide, however, while their cost savings are well established, their impact on driving performance has received little attention. This study investigated the effect of streetlight dimming on night-time driving performance. Participants included 14 licensed drivers (mean age 34.2 +/- 4.9 years, range 27-40 years) who drove an instrumented vehicle around a closed circuit at night. Six LED streetlights were positioned along a 250 m, straight section and their light output varied between laps (dimming levels of 25%, 50%, 75% and 100% of maximum output; L25, L50, L75 and L100 respectively; at 100% average road surface luminance of 1.14 cd/m(2)). Driving tasks involved recognition distances and reaction times to a low contrast, moving target and a pedestrian walking at the roadside. Participants drove at an average driving speed of 55 km/hr in the streetlight zone. Streetlight dimming significantly delayed driver reaction times to the moving target (F3,13.06 = 6.404; p = 0.007); with an average 0.4 s delay in reaction times under L25 compared to L100, (estimated reduction in recognition distances of 6 m). Pedestrian recognition distances were significantly shorter under dimmed streetlight levels (F3,12.75 = 8.27; p = 0.003); average pedestrian recognition distances were 15 m shorter under L25 compared to L100, and 11 m shorter under L50 compared to L100. These data suggest that streetlight dimming impacts on driver visibility but it is unclear how these differences impact on safety; future studies are required to inform decisions on safe dimming levels for road networks.  
  Address School of Chemistry, Physics and Mechanical Engineering, Faculty of Science and Engineering Faculty, Queensland University of Technology, Brisbane, Queensland, Australia  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0001-4575 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:30317014 Approved no  
  Call Number GFZ @ kyba @ Serial 2160  
Permanent link to this record
 

 
Author Cai, W.; Yue, J.; Dai, Q.; Hao, L.; Lin, Y.; Shi, W.; Huang, Y.; Wei, M. url  doi
openurl 
  Title The impact of room surface reflectance on corneal illuminance and rule-of-thumb equations for circadian lighting design Type Journal Article
  Year 2018 Publication Building and Environment Abbreviated Journal Building and Environment  
  Volume 141 Issue Pages (down) 288-297  
  Keywords Lighting  
  Abstract Recently, corneal illuminance attracts much attention because it is closely related to important functions of indoor lighting. Especially, applying circadian light in the built environment places a challenging requirement on indirect corneal illuminance. In this work, rule-of-thumb equations are proposed to guide circadian lighting design: (i) for artificial lighting, Ecor,avg (i) = (Φ/C1) · ρ/(1−ρ′), where Ecor,avg (i) is the average indirect corneal illuminance at standing or sitting positions, Φ is the initial flux from luminaires, C1 is a constant comparable to the total room surface area, ρ is the reflectance of the surface where the first reflection occurs, and ρ′ is the area-weighted average of surface reflectance; and (ii) for daylighting, Ecor,avg (i) = C2 · WWR · ρ/(1−ρ′), where C2 is a constant, and WWR represents the window-to-wall ratio.

The equations above are validated by comparing against numerical simulation data obtained with the Radiance software. For artificial lighting simulation, various combinations of room surface reflectance, initial light distribution, and WWR are investigated; and for daylighting simulation, different combinations of surface reflectance, WWR, and geographic location are analyzed. The good fits to simulation data indicate that the proposed simple equations can provide reasonably accurate results for quick feedback at the field. It is also demonstrated that room surface reflectance has a dominant impact on indirect corneal illuminance. The approach of improving surface reflectance is more favorable than increasing luminaire flux or expanding window area, and therefore should be the recommended approach to achieve quality and efficient circadian lighting.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0360-1323 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 1929  
Permanent link to this record
 

 
Author Jones, B.A. url  doi
openurl 
  Title Spillover health effects of energy efficiency investments: Quasi-experimental evidence from the Los Angeles LED streetlight program Type Journal Article
  Year 2018 Publication Journal of Environmental Economics and Management Abbreviated Journal Journal of Environmental Economics and Management  
  Volume 88 Issue Pages (down) 283-299  
  Keywords Human Health; LED; public health; outdoor lighting; Los Angeles; economics; energy efficiency; breast cancer; fossil fuel carbon emissions  
  Abstract Payback estimates of energy efficiency investments often ignore public health externalities. This is problematic in cases where spillover health effects are substantial, such as when the application of new technology alters environmental exposures. When health externalities are included in return on investment calculations, energy efficiency programs may look more or less attractive than suggested by conventional “energy savings only” estimates. This analysis exploits the quasi-experiment provided by the 2009 Los Angeles (LA) LED streetlight efficiency program to investigate the returns on investments inclusive of an originally estimated health externality. Using the synthetic control method, we find that the LED streetlight program is associated with a lagged increase in breast cancer mortality of 0.479 per 100,000. Inclusive of the effects of LEDs on breast cancer and avoided carbon emissions, the LA LED program provides a −146.2% 10-year return compared to +118.2% when health outcomes and carbon emissions are ignored.  
  Address Department of Economics, University of New Mexico, 1 UNM Drive, MSC 05 3060, Albuquerque, NM, 87131, USA; bajones(at)unm.edu  
  Corporate Author Thesis  
  Publisher Elsevier Place of Publication Editor  
  Language English Summary Language English Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0095-0696 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number IDA @ john @ Serial 1976  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: