toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links (up)
Author Fu, D.; Xia, X.; Duan, M.; Zhang, X.; Li, X.; Wang, J.; Liu, J. url  doi
openurl 
  Title Mapping nighttime PM 2.5 from VIIRS DNB using a linear mixed-effect model Type Journal Article
  Year 2018 Publication Atmospheric Environment Abbreviated Journal Atmospheric Environment  
  Volume 178 Issue Pages 214-222  
  Keywords Remote Sensing  
  Abstract Estimation of particulate matter with aerodynamic diameter less than 2.5 μm (PM2.5) from daytime satellite aerosol products is widely reported in the literature; however, remote sensing of nighttime surface PM2.5 from space is very limited. PM2.5 shows a distinct diurnal cycle and PM2.5 concentration at 1:00 local standard time (LST) has a linear correlation coefficient (R) of 0.80 with daily-mean PM2.5. Therefore, estimation of nighttime PM2.5 is required toward an improved understanding of temporal variation of PM2.5 and its effects on air quality. Using data from the Day/Night Band (DNB) of the Visible Infrared Imaging Radiometer Suite (VIIRS) and hourly PM2.5 data at 35 stations in Beijing, a mixed-effect model is developed here to estimate nighttime PM2.5 from nighttime light radiance measurements based on the assumption that the DNB-PM2.5 relationship is constant spatially but varies temporally. Cross-validation showed that the model developed using all stations predict daily PM2.5 with mean determination coefficient (R2) of 0.87 ±± 0.12, 0.83 ±0.10±0.10, 0.87 ±± 0.09, 0.83 ±± 0.10 in spring, summer, autumn and winter. Further analysis showed that the best model performance was achieved in urban stations with average cross-validation R2 of 0.92. In rural stations, DNB light signal is weak and was likely smeared by lunar illuminance that resulted in relatively poor estimation of PM2.5. The fixed and random parameters of the mixed-effect model in urban stations differed from those in suburban stations, which indicated that the assumption of the mixed-effect model should be carefully evaluated when used at a regional scale.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1352-2310 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1814  
Permanent link to this record
 

 
Author Neri, L.; Coscieme, L.; Giannetti, B.F.; Pulselli, F.M. url  doi
openurl 
  Title Imputing missing data in non-renewable empower time series from night-time lights observations Type Journal Article
  Year 2018 Publication Ecological Indicators Abbreviated Journal Ecological Indicators  
  Volume 84 Issue Pages 106-118  
  Keywords Remote Sensing  
  Abstract Emergy is an environmental accounting tool, with a specific set of indicators, that proved to be highly informative for sustainability assessment of national economies. The empower, defined as emergy per unit time, is a measure of the overall flow of resources used by a system in order to support its functioning. Continuous time-series of empower are not available for most of the world countries, due to the large amount of data needed for its calculation year by year. In this paper, we aim at filling this gap by means of a model that facilitates reconstruction of continuous time series of the non-renewable component of empower for a set of 57 countries of the world from 1995 to 2012. The reconstruction is based on a 3 year global emergy dataset and on the acknowledged relationships between the use of non-renewables, satellite observed artificial lights emitted at night, and Gross Domestic Product. Results show that this method provides accurate estimations of non-renewable empower at the country scale. The estimation model can be extended onward and backward in time and replicated for more countries, also using higher-resolution satellite imageries newly available. Besides representing an important advancement in emergy theory, this information is helpful for monitoring progresses toward Sustainable Development and energy use international goals.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1470160X ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1706  
Permanent link to this record
 

 
Author Kumar, P.; Sajjad, H.; Joshi, P.K.; Elvidge, C.D.; Rehman, S.; Chaudhary, B.S.; Tripathy, B.R.; Singh, J.; Pipal, G. url  doi
openurl 
  Title Modeling the luminous intensity of Beijing, China using DMSP-OLS night-time lights series data for estimating population density Type Journal Article
  Year 2018 Publication Physics and Chemistry of the Earth, Parts A/B/C Abbreviated Journal Physics and Chemistry of the Earth, Parts A/B/C  
  Volume 109 Issue Pages 31-39  
  Keywords Remote Sensing  
  Abstract Various scientific researches were conducted to monitor human activities and natural phenomena with the availability of various night time satellite data such as Defense Meteorological Satellite Program (DMPS). Population growth especially in a faster growing economy like China is an important indicator for assessing socio-economic development, urban planning and environmental management. Thus, spatial distribution of population is instrumental in assessing growth and developmental activities in Beijing city of China. The satellite observation data derived from Defense Meteorological Satellite Program (DMSP) was utilized to estimate population density through the measurement of light flux with radiometric recording. The data was calibrated using C0, C1, C2 parameters before processing. Population density of Beijing city was estimated using light volume of this calibrated data. Regression analysis between urban population and light volume revealed high correlation (r2=0.89)r2=0.89). Thus, population density can effectively be estimated using light intensity. The model used for estimating urban population density can effectively be utilized for other major cities of the world.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1474-7065 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 1934  
Permanent link to this record
 

 
Author Massetti, L. url  doi
openurl 
  Title Assessing the impact of street lighting on Platanus x acerifolia phenology Type Journal Article
  Year 2018 Publication Urban Forestry & Urban Greening Abbreviated Journal Urban Forestry & Urban Greening  
  Volume 34 Issue Pages 71-77  
  Keywords Plants  
  Abstract Autumn phenology is an important part of the tree growing season that is still poorly understood. In addition to the environmental factors that might affect its timing, there are artificial effects introduced by modern society that could interfere with it, such as the increasing use of artificial light to illuminate urban nights. This study investigates the relationship between outdoor public lighting and leaf senescence of Platanus x acerifolia that constitutes with more than 4000 individuals, and 6% of public greening in Florence, Italy. The difference in autumn phenology under two lighting conditions was assessed by analysing data collected in a real context, using a presence-absence protocol of green leaves on 283 trees during leaf fall season from 2014 to 2017. Trees were classified in two groups of different light exposure. In 2016-2017, data were also collected at Cascine park, the main green area within the city and darker than the monitored sites. According to the analysis, the percentage of trees with green leaves under luminaires was significantly higher than trees far from the luminaires, for all sites from mid-December to the end of January, and this effect was enhanced during 2016-2017 which was characterised by a colder winter. In the same year, the period of absence of green leaves at Cascine started at least 20 days earlier than the other sites. These findings should be taken into consideration by scientists because artificial light could affect autumn phenology and therefore the length of the vegetative season, and by urban greening and light managers during the design and management of public green spaces. Moreover, the presence-absence protocol proved to be suitable for collecting observations because it was easy to perform in a real context.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1618-8667 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 1932  
Permanent link to this record
 

 
Author Weisbuch, C. url  doi
openurl 
  Title Historical perspective on the physics of artificial lighting Type Journal Article
  Year 2018 Publication Comptes Rendus Physique Abbreviated Journal Comptes Rendus Physique  
  Volume 19 Issue 3 Pages 89-112  
  Keywords History; Lighting  
  Abstract We describe the evolution of lighting technologies used throughout the ages, and how the need for improvements was such that any new technology giving better and cheaper lighting was immediately implemented. Thus, every revolution in energy sources – gas, petrol electricity – was first put to large-scale use in lighting. We describe in some detail several “ancient” techniques of scientific interest, along with their physical limitations. Electroluminescence – the phenomenon by which LEDs directly convert electricity into light – was long thought to only be of use for indicators or flat panel displays supposed to replace the bulky cathode-ray tubes. The more recent uses of LEDs were mainly for street traffic lights, car indicators, small phone displays, followed by backlighting of TV screens. LED lamps for general lighting only emerged recently as the dominant application of LEDs thanks to dramatic decrease in cost, and continuous improvements of color quality and energy conversion efficiency.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1631-0705 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 1840  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: